Bureau D' Electronique Appliquee Inc TD433 Benutzerhandbuch

Seite von 2
75.5092 V2 July 2003 [Rev. 11/24/2003]
 
 
                
 
Page 2 of 2 
COMPANY 
CONTACT
 
RECEIVER DIP 
SWITCH 
OPERATION
 
 
 
 
 
12 V
type A23
 
1.  Remove screw from back of transmitter 
2.  Separate housing and install a fresh 12-Volt Type 23A battery 
3.  Reassemble housing and replace screw. 
 
 
 
 
 
The transmitter may be used as a hand-held device, or may also be used with a push plate if supplied with two pre-
attached wires. To program the transmitter to the corresponding receiver, perform the following: 
Hand-Held Configuration 
For Use With Push Plate 
1.  On the 433MHz digital receiver, press the brown learn 
button once (the yellow LED will illuminate). 
2.  Within 20 seconds, press the button on the transmitter 
once (the yellow LED on the receiver will extinguish). 
3.  Press the transmitter button again (the yellow LED will 
flash for 2 seconds). 
4.  Press the transmitter button to verify receiver detection 
(the yellow LED will flash and the red LED will illuminate 
for the length of time set by the dipswitch). 
1. Before beginning, it is easiest to have already 
prepared the installation of the pushplate.  
2.  Connect the wires from the transmitter to the NO 
and COM contacts of the pushplate switch. 
3.  Follow step 1 from the ‘Hand-Held Configuration’ 
setup; depress the pushplate to activate the 
transmitter. 
4.  Attach the transmitter to the inside of the electrical 
box and complete the installation. 
 
 
 
 
 
 
 
 
 
 
• 
Shut off all power going to the header before attempting any wiring procedures. 
• 
Maintain a clean & safe environment when working in public areas. 
• 
Constantly be aware of pedestrian traffic around the door area. 
• 
Always stop pedestrian traffic through the doorway when performing tests that may result in 
unexpected reactions by the door. 
• 
Always check placement of all wiring before powering up to insure that moving door parts will not 
catch any wires and cause damage to equipment. 
• 
Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of 
installation. 
 
 
 
 
 
If after troubleshooting a problem, a satisfactory solution cannot be achieved, please call B.E.A., Inc. 
for further assistance during Eastern Standard Time at 1-800-523-2462 from 8am - 5pm.  
For after-hours, call East Coast: 1-866-836-1863 or 1-800-407-4545 / Mid-West: 1-888-308-8843 /  
West Coast: 1-888-419-2564. DO NOT leave any problem unresolved. If you must wait for the 
following workday to call B.E.A., leave the door inoperable until satisfactory repairs can be made.  
NEVER sacrifice the safe operation of the automatic door or gate for an incomplete solution. 
Web: www.beasensors.com 
DIPSWITCH 1 
DESCRIPTION 
FUNCTION 
ON 
MOMENTARY PULSE 
Press the transmitter once and the relay will be active momentarily 
OFF 
RATCHET RELAY 
Press the transmitter once, and the relay output is active 
indefinitely, press it again, and it will become passive. 
 
 
 
DIPSWITCH 2 
DESCRIPTION 
FUNCTION 
ON 
0.5 second Hold time  
Relay will remain active 0.5 seconds after the loss of activation 
OFF 
10 seconds Hold time 
Relay will remain active 10 seconds after the loss of activation 
PROGRAMMING
 
SAFETY 
PRECAUTIONS
 
INSTALLING / 
REPLACING THE 
BATTERY (12 Volt 
Models)