Climax Technology Co Ltd CTC1052RV Benutzerhandbuch

Seite von 41
32 
5.4. CTC-1052RV Programming Command Table 
 
DTMF 
CHARACTER 
COMMANDS 
DTMF 
ACK 
COMMAND OPERATION 
TERM
I- 
NATO
DTMF 
ACK 
DEFAULT 
01# Bi 
Telephone 
number 
Bi 
No number 
02# Bi 
Telephone 
number 
Bi 
No number 
03# Bi 
Telephone 
number 
Bi 
No number 
04# Bi 
Telephone 
number 
Bi 
No number 
05# Bi 
Telephone number & GPRS/IP for alarm report 
1=TEL1 , 2=TEL2 , 3=TEL3 , 4=TEL4,  
5=GPRS1 , 6=GPRS2 
# Bi 
1,2,3,4,5,6 
06# Bi 
Telephone number& GPRS/IP for status report 
1=TEL1 , 2=TEL2 , 3=TEL3 , 4=TEL4,  
5=GPRS1 , 6=GPRS2 
# Bi 
1,2,3,4,5,6 
07# 
Bi 
Telephone number for Non-Emergency Call 
Bi 
Disable 
10# Bi 
Global account number, 4 to 6 digits 
Bi 
No account number
11# Bi 
4-6 digits Account number 1 (Tel. Number 1) 
Bi 
No account number
12# Bi 
4-6 digits Account number 2 (Tel. Number 2) 
# Bi 
No account number
13# Bi 
4-6 digits Account number 3 (Tel. Number 3) 
Bi 
No account number
14# Bi 
4-6 digits Account number 4 (Tel. Number 4) 
Bi 
No account number
20# Bi 
All formats the same, 0 = Contact ID,  
1= Scancom, 2 = Tunstall, 3 = Speech, 4=SMS CID 
# Bi 
Contact ID 
21# Bi 
0 = Contact ID, 1= Scancom, 2 = Tunstall,  
3 = Speech, 4=SMS CID (Tel. Number 1) 
# Bi 
Contact ID 
22# Bi 
0 = Contact ID, 1= Scancom, 2 = Tunstall,  
3 = Speech, 4=SMS CID (Tel. Number 2) 
# Bi 
Contact ID 
23# Bi 
0 = Contact ID, 1= Scancom, 2 = Tunstall,  
3 = Speech, 4=SMS CID (Tel. Number 3) 
# Bi 
Contact ID 
24# Bi 
0 = Contact ID, 1= Scancom, 2 = Tunstall,  
3 = Speech, 4=SMS CID (Tel. Number 4) 
# Bi 
Contact ID 
31# Bi 
Ringer enable, 0 = Disable, 1 = Enable 
Bi 
Ringer Disabled 
32# Bi 
Audible fault alert, 0 = Off, 1 = On 
Bi 
Off 
33# Bi 
Help arrived signalling, 0 = Off, 1 = On 
Bi 
Help arrived 
signalling Off 
34# Bi 
Emergency button enable, 0 = Button off, 1 =Button 
on 
# Bi 
Emergency button 
On 
35# Bi 
Silent Mode, 0 = Silent mode On, 1 = Silent mode Off
Bi 
Silent mode Off 
37# Bi 
AC fault report, 0 = Off, 1 = On 
Bi 
On 
38# Bi 
Follow-On & Call Back Function, 0 = Follow-On, 1= 
Call-Back, 2= Follow-On & Call-Back 
# Bi 
Follow-On 
40# Bi 
Set Access Code 
Bi 
1111 
42# 
Bi 
Guard time delay, 00 = Instant; … 99 = 99 seconds 
Bi 
10 seconds 
43# Bi 
Test call, 0 = OFF, 1 = 1 Day, 2 = 2 Days,  
3 = 3 Days, 4 = 4 Days. 5 = 5 Days,  
6 = 6 Days, 7 = 7 Days, 8 = 30 days 
Bi 
No test call