DTMF
CHARACTER
COMMANDS
DTMF
ACK
COMMAND OPERATION
TERMI-
NATOR
DTMF
ACK
DEFAULT
44# Bi
Mobility time
00= Disable, 01 ~ 36= 1 ~ 36 Hours
00= Disable, 01 ~ 36= 1 ~ 36 Hours
# Bi
Mobility time
disable
45# Bi
Follow-On Choice, 0 = Wait command,
1 = Listen, 2 = Two way voice communication
1 = Listen, 2 = Two way voice communication
# Bi
Two-way voice
communication
46# Bi
Follow-On mode & Two-Way Period,
01=1 min, 02=2mins, 03=3mins, 04=4mins,
05=5mins, 06=6mins, 07=7mins, 08=8mins,
09=9mins, 10=10mins.
05=5mins, 06=6mins, 07=7mins, 08=8mins,
09=9mins, 10=10mins.
# Bi 5
minutes
47# Bi
Off-set time, 1=1 hour, 2=2 hours, 3=3 hours,
4=4 hours, 5=8hours, 6=12 hours
4=4 hours, 5=8hours, 6=12 hours
# Bi
1
Hour
49# Bi
Supervision, 0 = disable, 1 = 4 days, 2 = 5 days, 3 =
6 days,4 = 7 days, 5 = 8 days, 6 = 9 days, 7 = 10 days
6 days,4 = 7 days, 5 = 8 days, 6 = 9 days, 7 = 10 days
# Bi
Disable
Dual-band mode
900 extended
(900E)/1800 MHz
(Europe)
60# Bi
GSM Band Select
0=Mono-band mode 850 MHz (U.S.)
1=Mono-band mode 900 extended (900E) MHz
(Europe)
2=Mono-band mode 1800 MHz (Europe)
3=Mono-band mode 1900 MHz (U.S.)
4=Dual-band mode 850/1900 MHz (U.S.)
0=Mono-band mode 850 MHz (U.S.)
1=Mono-band mode 900 extended (900E) MHz
(Europe)
2=Mono-band mode 1800 MHz (Europe)
3=Mono-band mode 1900 MHz (U.S.)
4=Dual-band mode 850/1900 MHz (U.S.)
5=Dual-band mode 900 extended (900E)/1800 MHz
(Europe)
6=Dual-band mode 900 extended (900E)/1900MHz
(Europe/U.S.)
(Europe)
6=Dual-band mode 900 extended (900E)/1900MHz
(Europe/U.S.)
# Bi
Dual-band mode
850/1900 MHz (U.S.)
61# Bi
Check SIM CARD PIN CODE
0: Disable
1: Enable
0: Disable
1: Enable
# Bi
Disable
62#
Bi
Set Input SIM CARD PIN CODE : 4 ~ 8 digital
#
Bi
Null
63# Bi
Set Speaker Volume
Enter: Mode Number + *+ Speaker Volume
Note: Mode Number: 1 digit (2:Two-way)
Enter: Mode Number + *+ Speaker Volume
Note: Mode Number: 1 digit (2:Two-way)
Speak volume: 1 digit (1~5 level)
#
Bi
Two way mode: 3
64# Bi
Set Microphone Sensitivity:
Note: Mic sensitivity: 1 digit (1~5 level)
Note: Mic sensitivity: 1 digit (1~5 level)
Only can be adjusted in the two-way mode.
#
Bi
Two way Mode: 3
66# Bi
Guard time delay for Fall Sensor, 00 = Instant
reporting; … 99 = 99 seconds
reporting; … 99 = 99 seconds
# Bi
15
sec
80#
Bi
Remove all device (learnt in Command 91-94)
---
---
---
81#
Bi
Remove pendant #1 (learnt in Command 91)
---
---
---
82#
Bi
Remove pendant #2 (learnt in Command 92)
---
---
---
83# Bi
Remove Silent Pendant
(learnt in Command 93)
(learnt in Command 93)
--- ---
---
84#
Bi
Remove the Devices (learnt in Command 94)
---
---
---
91#
Bi
Learn-in pendant #1
---
Bi Bi
No device
92#
Bi
Learn-in pendant #2
---
Bi Bi
No device
93#
Bi
Learn-in silent emergency transmitters
---
Bi Bi
No device
94# Bi
Learn-in smoke detectors, CO detectors,
pendants and fixed emergency transmitters, long
range pendants
pendants and fixed emergency transmitters, long
range pendants
---
Bi Bi
No device
98# Bi
Load defaults when ** is pressed (DTMF A is
heard after defaults have been loaded)
heard after defaults have been loaded)
# Bi
---
99#
Bi
Exit programming mode
---