Exiting the Installer Options
When done, press the COMMAND key once to return to the Installer Options screen.  Press the Select key under STOP 
to exit the Installer Options function.
Programming Cards into the System
From the User Menu, select USER CODES?.  Choose ADD.  At the ENTER CODE: - display, present the user card to the 
reader.  The keypad works by reading the 4 or 5-digit user code from the data sent by the access control reader.  For 
more information, refer to the panel user’s guide section on adding, deleting, and changing user codes.
Additional Power Supply
If the current draw for all keypads exceeds the panel output, you can provide additional current by adding a Model 
505-12 auxiliary power supply.  Connect all keypad common wires to the negative terminal of the power supply.  Run 
a jumper wire from the power supply negative terminal to the panel common terminal.  Connect all keypad power 
(+12 VDC) wires to the power supply positive terminal.  Do NOT connect the power supply positive terminal to any 
panel terminal.  Refer to the 504-24 and 505-12 Power Supply Installation Guide (LT-0453) for more information. 
701 and 793 Door Strike Relay SpeciÞ cations
The Easy Entry keypads provide one internal Form C single pole, double throw (SPDT) relay for controlling door 
strikes or magnetic locks.  Three wires on the 5-wire harness, Violet (N/C), Gray (Com), and Orange (N/O), allow you 
to connect devices to the relay.
The Form C relay draws up to 30mA of current and its contacts are rated for 1 Amp at 24 VDC.
Access the User Menu
You can also use a card reader to access the User Menu.  When the MENU?  NO YES displays, present your proximity 
card to the reader.
Door Strike Relay Operation
As soon as the user code sent from the reader has been veriÞ ed by the panel, the keypad Door Strike relay activates 
for Þ ve seconds.  During this time, the access door connected to zone 2 must be opened to start the 40-second 
entry/exit timer and zone soft shunt.  See the timeline shown below.
Note: The 5-second delay length is programmable when the keypad is used on an XR200-485 or XR500/XR500N.
5 Second
Strike
40-Second "Soft-Shunt"
and entry/exit timer.
At 30 seconds,
the keypad beeps
if door is still open.
End of 
timer.
40
Seconds
A zone fault is indicated
if door is still open.
Figure 7: Door Strike Relay operation time line
User’s Guide
There are three different operating modes: Door Strike, 
Arming and Disarming, and Entry Delay. All of the 
examples below assume that CLOSING CODE is YES in panel 
programming.
Door Strike
Area and All/Perimeter Door Strike.  From the Status List, 
present your card to the reader. Once the system validates 
the card, the Door Strike relay activates. See Door Strike 
Relay Operation above. Home/Away systems only activate 
the Door Strike relay when arming and disarming.
         
 ABC 
SECURITY
ARM  
DISARM
While the keypad is in
the Status List, present
your access card.
The relay activates for 5 seconds during
which time you can open the door.
Once you open the door, you have 40
seconds to exit and close the door 
before the Zone 2 Soft-Shunt expires.