Digital Monitoring Products Inc PC0132 Benutzerhandbuch
6
9800 Series Keypad Installation Guide
Mounting the Keypad
Secure the keypad base to the wall ensuring that the wall tamper switch makes
proper contact with the wall. Use the supplied screws in the mounting hole locations
as shown in Figure 9.
Primary DC Power Supply
Figure 10 shows the Model 373-500 plug-in DC power supply connector. The plug-in
power supply provides a six foot cord. The cord may be lengthened, but should be
located within 100 feet of the keypad using 22 AWG wire. For ease of connection,
locate the keypad near a wall outlet.
In addition to powering the keypad, the power supply also charges the internal back-
In addition to powering the keypad, the power supply also charges the internal back-
up battery.
OBSERVE POLARITY WHEN EXTENDING THE POWER SUPPLY CORD.
Firmly grasp the wires near the base of the connector and
hold the outside edges of the keypad housing. Connect the
power supply to the J5 header on the 9800 Series Wireless
Graphic Touchscreen Keypads.
Note: Do not remove the PCB from the keypad housing to
Note: Do not remove the PCB from the keypad housing to
install the power supply connector.
When the power supply connector is plugged into the keypad,
When the power supply connector is plugged into the keypad,
the internal battery is automatically connected. The keypad
can operate from battery only as long as the power supply
connector is plugged into the keypad.
Figure 9: 12 Vdc Wiring
White – Connect Reader Data 1
Orange – Door Strike Normally Open
Gray – Door Strike Common
Violet – Door Strike Normally Closed
Black – Ground
Red – Keypad Power
External Card
Reader
Green/White – Connect Reader Data 0
Black/White
Black
Surface and Backbox
Mounting Holes
Keypad Back
To A/C
Power
Supply
Tamper
Keypad Back
J5
Black
/White
Stripe (+)
Black
(-)
Figure 10: Installing
the Wiring Harness