The RF6GB is a wireless glassbreak detector intended for use with Honeywell controls that support SiX™ 
Series devices. 
Mounting 
 
The RF6GB can be mounted 
on the wall or on the ceiling. 
  within 7.6 m (25 feet) of the 
protected glass; 
  within clear view of the 
protected glass; 
  at least 2 m (6.5 feet) from the 
floor; 
  at least 1 m (3.3 feet) from 
forced air ducts; 
  at least 1 m (3.3 feet) from 
sirens or bells greater than 5 
cm (2 inches) in diameter. 
  between the protected glass 
and any heavy window 
coverings. 
  when heavy window coverings 
are present, the detector can 
be mounted on the window 
frame. 
  Avoid mounting the detector 
on the same wall as the 
protected glass, on free-
standing posts or pillars, or in 
rooms with noisy equipment 
(air compressors, bells, power 
tools, etc.), if this equipment is 
operated when the detector is 
armed. 
  UL requirements:  
TBD
 
 
  
 
To remove the mounting bracket: 
Turn the top of the detector 15 degrees 
counter-clockwise and separate the 
mounting bracket. 
Note: Before mounting the RF6GB 
permanently, conduct Go/No Go tests (see 
control’s instructions) to verify adequate 
signal strength and adjust the device location 
and orientation as necessary. 
  The RF6GB can be mounted on the wall 
or on the ceiling. 
  The rear tamper plate MUST be mounted 
to a stud, solid wood, or with a robust 
wall anchor. 
 
 