RF6GB LEDs 
The RF6GB has three LEDs which are visible 
when the unit is mounted. 
Green 1 LED indicates device enrollment and 
tamper status. 
The Red and Green 2 LEDs provide information 
on detector status during Test Mode. The Green 
2 LED indicates events and the Red LED 
indicates Alarms.  
LED Indications Table 
 
 
G1 
Red 
G2 
Status 
 
 
 
1
 
Test Mode
2
 
 
 
 
Event detected during Test Mode 
 
 
 
Alarm detected during Test Mode 
 
3
 
3
 
Low Battery detected during Test Mode 
 
 
 
Power Up / Tamper switch pressed / FG-701 Activated before enrollment 
 
 
 
Tamper Detected 
1
 If RF6GB Test Mode is activated by the FG701, the Green 2 LED will flicker, then be off for 3 seconds, then flash once per second. 
2
 Test Mode lasts for 10 minutes. 
3
 This feature is used for field diagnosis.  The LEDs are not visible during Normal Mode to save power. 
 
 
Test the RF6GB  
The RF6GB should be tested after installation and at least 
once a year. 
Test Mode can be activated remotely from the Control 
Panel (see Control Panel manual), or on-site with an FG-
701 Glassbreak Simulator, only when the system is 
disarmed. 
Follow directions in the FG-701 Glassbreak Simulator 
Operating Instructions to activate and test the RF6GB 
detector. 
 
Battery Replacement 
  Twist the front cover counterclockwise 15 
degrees and separate from the mounting 
bracket.  
  Remove and replace the battery. 
Recommended replacement batteries:  
Panasonic CR123A 
Honeywell 466 
Duracell DL123 
Duracell DL123A 
  Reattach the front cover and twist it 15 
degrees clockwise to lock it in place.  
BATTERY CAUTION: Risk of fire, explosion and burns.  
Do not recharge, disassemble, heat above 100
° C (212° F) 
or incinerate. Dispose of used batteries promptly. Keep 
away from children.