Environmental requirements
Overview
The Alcatel-Lucent B25 RRH4x30 can only be mounted on a wall or a pole (64 mm to
115 mm (2.5 in to 4.5 in) diameter pipe). Other mounting options are currently not
available. The Alcatel-Lucent B25 RRH4x30 requires certain clearance, thermal, and
mechanical provisions described in this chapter.
Operating environment
The Alcatel-Lucent B25 RRH4x30 is weather-hardened, which enables it to operate in
environments within the conditions described in the following table.
Condition
Specification
Operating temperature
−40°C (−40°F) to +55°C (+131°F)
Relative humidity
Except for low temperature and high
temperature, 5 to 100% (condensing and high
absolute humidity of 36 g/m
3
)
Operating altitude
–61 m (–200 ft) to 3960 m (13,000 ft),
referenced to sea level
Extended operating altitude
For altitudes between 1829 m (6000 ft) and
3960 m (13,000 ft), the maximum operating
ambient temperature may be derated by 1°C
for each 300 m interval above 1829 m (no
temperature derating below 1829 m).
Ingress protection
IP65
Enclosure rating
NEMA Type 4
Wind driven rain
GR-487-CORE tested with MIL-STD 810G
method 506.5, rainfall rate 15 cm/hour and
wind 33 meter/sec
Wind speed
Rated: 150 km/hour (93 mi/h)
Maximum (survival): 240 km/h (150 mi/h)
Wind load (at 150 km/h or 93 mi/h)
Frontal: less than 200 N
Lateral: less than 150 N
Earthquake
Zone 4
Touchable exterior surfaces
Surface temperatures not to exceed 70°C
Corrosion resistance
Temperature Cycling/Humidity requirements
per GR-487-CORE
Salt Fog per GR-487-CORE, Section 3.40