External clearances
Minimum clearances
The following table provides the minimum clearances recommended around the
Alcatel-Lucent B25 RRH4x30.
Side
Minimum clearance
— mm
(inches)
Comments
Front
1000 (39.4)
Installation access
50 (2)
Air flow
Right
210 (8.2)
Air flow
Left
210 (8.2)
Air flow
Top
300 (11.8)
Air flow
Bottom
400 (15.7)
Cable routing
Notes:
1.
Minimum clearance values are not cumulative. For example, if two RRHs are installed side
by side (adjacent to each other) on a wall, the minimum distance between them must be
210 mm (not 420 mm).
2.
Measured from the mounting surface to the tips of the cooling fins on the back of the
Alcatel-Lucent B25 RRH4x30. For wall mounting, the rear clearance is defined by the
mounting bracket and wall mounting hardware.
Environmental and mounting requirements
External clearances
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-4
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
B25 RRH4x30
3MN-02023-0001-RJZZA
Issue 0.02
January 2015