The following list specifies outdoor requirements for short antenna cable runs:
• If the cable length between the RRH and the antenna is 32 ft or less, then grounding
of the antenna cable is optional.
• External surge suppression is also optional and can be mounted directly to the
Alcatel-Lucent B25 RRH4x30.
Note: If an AISG Bias Tee device will be installed and surge protection is desired,
then only a hybrid surge protector is required on the path with the Bias Tee.
Indoor requirements
The following list indoor requirements for the antenna cable runs.
• The cable must be grounded at the antenna, at any transition points between cables
outside of the building, and at the entrance to the building; additionally the cable span
must be grounded every 30 meters.
• External surge suppression at the hatchplate is recommended. Refer to the figure
below.
Note: If an AISG Bias Tee device will be installed and surge protection is desired,
then only a hybrid surge protector is required on the path with the Bias Tee.
Antenna interface
Antenna cable grounding and optional surge suppression
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
6-6
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
B25 RRH4x30
3MN-02023-0001-RJZZA
Issue 0.02
January 2015