INSTALLATION
2-3
August 2000
Part No. 001-2001-200
2.6.1  AC INPUT REQUIREMENTS
AC Input Voltage:
100-240V AC
Line Frequency:
50-60 Hz
AC In-rush:
60A maximum
Overall Efficiency:
>70% at 100V AC
>80% at 240V AC
Lightning protection:
6kV for < 1ms
Power Factor:
>0.97 at full load
Brown Out Voltage:
80V AC
Temperature
-30°C - +60°C (full power)
Power factor correction per IEC555.  The Power 
supply has the following safety agency approvals 
pending:  UL1950, CSA22.2-950, TUV EN60950 
(IEC950)
When the AC input voltage is below 90V AC, the 
maximum output power is decreased to keep the input 
current constant.  If a battery back-up is installed, the 
batteries take over when the AC input voltage falls 
below 80V AC (dependant on power output).
The AC input connector is an IEC connector 
equipped with a locking mechanism.
Table 2-1   OUTPUT VOLTAGES
Voltage
Current
Wattage
+26.5V
22A
583W
+15V
5A
75W
+5.2V
5A
26W
-5V
1A
5W
Table 2-2   OVER VOLTAGE
Voltage
Range
+26.5V
+32V to +33V
+15V
+16V to +18V
+5.2V
+6V to +7V
-5V
-6V to -7V
Figure 2-3   POWER CABLE CONNECTOR AND SCHEMATIC
9
7
12
11
10
8
6
5
4
3
2
1
A
B
C
J2
1
2
3
4
5
6
7
8
9
REPEATER
BACKPLANE
AC FAIL IN
POWER SWITCH
THERMAL SENSOR
+15V
N/C
N/C
-5V
TO
POWER HARNESS
GROUND
+15V
+5V
TO
RFIB
+26.5V
A
B
C
1
2
3
4
5
6
7
8
9
10
11
12
3
6
9
8
5
2
1
4
7
J2
BACKPLANE
N/C