E F Johnson Company 2424140 Benutzerhandbuch

Seite von 73
RADIO-WIDE FEATURES
26
. Then pressing F2 again takes the channel out 
of the scan list. Refer to Sections 5.11.3 and 6.12.2 
for more information on priority channel sampling.
6. To exit this mode and save the changes, press the F1 
(Exit) key or the Scan Edit option switch again.
7.
4.9.2  RADIO WIDE SCAN LISTS
General
With radio wide scanning, there is only one scan 
list available regardless of the type of channel selected. 
This list is user programmable in later units, and can 
contain up to 16 channels of any type. For example, it 
could include six conventional channels and ten 
SMARTNET/SmartZone channels. More information 
on selecting and editing radio wide scan lists follows.
Determining Channels in Radio Wide Scan List
The channels in radio wide scan lists are deter-
mined by selecting the scan list edit mode (see 
“Editing Radio Wide Scan List” which follows).
When the displayed channel is in the radio wide 
scan list (scanned normally), the 
 icon is 
displayed. 
Editing a Radio Wide Scan List
If the RWS Edit option switch or menu param-
eter is programmed, the radio wide scan list can be 
edited. Changes are permanent (cycling power does 
not reselect a default condition). Proceed as follows:
1. Make sure that both priority and radio wide scan-
ning are off (
 icon not displayed). Select the 
scan edit mode using the RWS Edit option switch or 
menu parameter. This mode is indicated by 
 in 
the display. 
2. Select the channel you want to add or delete by 
pressing the Up/Down switch. After the last channel 
in the current zone is displayed, the first valid 
channel in the next zone is displayed and vice versa. 
Lists are limited to 16 channels. If an attempt is 
made to add more than 16, “LIST FULL” is 
displayed and a channel must be deleted before 
another can be added. 
3. If the selected channel is in the scan list (scanned), 
the 
 icon is displayed. To change the status of 
the displayed channel, press the F2 (Enter) switch.
4. To exit this mode and save the changes, press the F1 
(Exit) key or the RWS Edit option switch again.
2