E F Johnson Company 2425331 Benutzerhandbuch

Seite von 66
CONVENTIONAL FEATURES
34
5.16.2  MENU STRUCTURE
A menu system is used to select parameters in the 
keypad programming mode. A flowchart showing the 
keypad programming mode menu structure is located 
in Figure 5-1. When the keypad programming mode is 
selected by the PROG option switch, “CHNG ZONE” 
is displayed as just described. Rotate and press the 
Select switch to scroll through and select the available 
parameters which are as follows. 
CHNG ZONE 
CHNG CHAN 
SYS PARMS 
CHAN PARMS 
Press the Select switch to select the displayed 
parameter. Pressing the PROG option switch from one 
of the main menus exits keypad programming. 
Pressing it from other menus returns to the previous 
menu. Refer to the descriptions which follow for more 
information.
Figure 5-1   5300 Keypad Programming Menu 
Flowchart
5.16.3  ZONE PASSWORD
NOTE: Make sure that the zone password(s) are not 
lost because they cannot be overridden in the field. 
The PCConfigure software must be used to display the 
lost password or program a new password.
Each zone can be programmed with a password 
by the PCConfigure software to prevent unauthorized 
reprogramming of zone by keypad programming. 
When this password is programmed, it must be entered 
before system or channel parameters in that zone can 
be changed by keypad programming. The zone pass-
word is programmed in the Zones > Edit Zone screen 
of the PCConfigure programmer. This screen is 
displayed by clicking the Edit Zone button. A different 
password can be programmed for each zone. 
When an attempt is made to select a system or 
channel parameter in a password protected zone, 
“PASSWORD” is flashed. The password is always 
eight digits long and is entered using the same proce-
dure as used for the power-up password described in 
Section 3.2. After the password is entered, system and 
channel parameters for that zone can be reprogrammed 
normally.
5.16.4  ZONE CHANGE PARAMETER
The “CHNG ZONE” menu parameter selects the 
zone containing the conventional channel to be repro-
grammed. It does not change the zone selected for 
normal operation. 
Press the Select switch to select the “CHNG 
ZONE” parameter and then scroll through the 
programmed zones by rotating that switch. When the 
desired zone is displayed, select it by pressing the 
Select switch.
5.16.5  CHANNEL CHANGE PARAMETER
The “CHNG CHAN” menu parameter selects the 
conventional channel to be reprogrammed. Disabled or 
P25 Trunked/SMARTNET/SmartZone channels 
cannot be selected. This does not change the channel 
selected for normal operation.
Press the Select switch to display “CHAN CHG” 
and then scroll through the programmed channels by 
rotating that switch. When the desired channel is 
displayed, select it by pressing the Select switch. 
5.16.6  SYSTEM PARAMETERS
NOTE: If “PASSWORD” is briefly displayed when 
attempting to select a parameter, see Section 5.16.3. 
The “SYS PARMS” menu parameter selects the 
conventional mode timer to be reprogrammed (see 
following). Press the Select switch to select “SYS 
Change
Change
Channel
Zone
System 
Parameters
Channel
Parameters
Select
Zone
Select
Channel
Scan Hold Timer
Tx (Time-Out) Timer
Penalty Timer
Conver. Timer
Rx Freq
Tx Freq
Rx Code/NAC
Tx Code/NAC
Tx Power
Tx Timer On-Off
Squelch Adj*
Ch Spacing*
Tlk Grp ID Sel**
* Analog only      ** Digital only
Tx Type Sel***
*** Mixed Mode Ch Only