SmartZone operation, the control channel data rate 
is 3600 baud (both digital and analog calls) and the 
narrowband digital voice data rate is 9600 baud.
The P25 mode uses a system ID, Wide Area 
Communications Network (WACN) ID, and RF 
Subsystem ID (RFSS). The SmartZone mode does 
not use the WACN and RFSS IDs.
P25 Unit IDs can be 1-16,777,215 (000001-FFFFFF 
hex) and SmartZone Unit IDs can be 1-65,535 
(0001-FFFF hex).
3.7.5  SYSTEMS, CHANNELS, AND ZONES
A zone and channel are selected to place and 
receive calls. The following describes the relationship 
between systems, channels, and zones.
Systems
A system is a collection of channels or talk 
groups belonging to the same repeater site. It defines 
all the parameters and protocol information required to 
access a site. Up to 16 systems of any type can be 
programmed. 
The maximum number of channels assignable to 
a system is limited to 256. Channels may also be 
limited by available memory space as described in the 
following information.
Channels
A channel selects a radio (RF) channel or talk 
group as follows:
Conventional Analog Mode - A channel selects a 
specific radio channel, Call Guard (CTCSS/DCS) 
squelch coding, and other parameters unique to that 
channel.
Conventional Project 25 Mode - A channel selects a 
specific radio channel, NAC squelch coding, talk 
group ID, and other parameters unique to that channel. 
Mode - A channel selects a specific talk group ID and 
other parameters unique to that talk group.
SMARTNET/SmartZone and Trunked Project 25 
Modes -
 A channel selects a specific talk group, 
announcement group, emergency group, and other 
parameters unique to that talk group.
A maximum of up to approximately 256 channels 
can be programmed with the preceding modes. These 
channels can belong to a single system or multiple 
systems. The maximum number is also limited by the 
available memory. For example, since more memory is 
required to program a SMARTNET system than a 
conventional system, the total number of channels 
decreases as the number of SMARTNET channels 
increases. The programming software displays a bar 
graph which shows the amount of available memory 
space that is used by the current data. 
Zones
A zone is a collection of up to 16 channels of any 
type. For example, a zone could include 12 conven-
tional channels and 4 SMARTNET channels. One use 
of zones may be to program the channels used for 
operation in a different geographical areas. The 
maximum number of zones is 16.