In addition, with the Handheld Control Unit (HHC) only, conventional systems can be 
programmed for the Keypad CTCSS/DSC feature. Codes can then be selected directly 
from the table by pressing the key for the code. For example, to select code 3 from the 
table, simply press the “3” key. No other conventional mode functions can then be 
assigned to these keys.
The CTCSS/DCS/NAC list is programmed with up to 64 tone (CTCSS) or digital (DCS) 
Call Guard codes. Different codes can be programmed for the transmit and receive modes, 
and carrier squelch (selective squelch disabled) can be programmed if desired. In addition, 
each position can be programmed with an NAC code for use with P25 operation.
When the Call Guard code is changed using this feature, it remains selected even if other 
channels are selected. However, if radio power is cycled or a talk-around channel is 
selected, the normal codes are reselected. When scanning, the selected code also applies to 
all scanned channels. Each channel can also be programmed to always ignore the code 
selected from this list and use the default code instead.
If both analog and digital (Project 25) channels can be selected or scanned, the CTCSS/
DCS code for the selected position is used for analog channels and the NAC code for the 
selected position is used for P25 channels. If a channel is programmed for mixed mode 
operation, the selective squelch type (analog or digital) programmed for the transmit mode 
determines the selective squelch type used.
Proceed as follows to select a code using the SQ LIST option switch:
Press the SQ LIST option switch and then rotate the Select switch to select the desired 
position. The display indicates “SEL SQ xx” where, “xx” is the selected code from 1-
64. The code number and actual code are alternately displayed (NACs are displayed in 
hexadecimal).
To select the displayed code and return to the normal display, press the Squelch Code 
Select switch again.
To check which code is selected, press the SQ LIST option switch once to display the 
current selection and then again to return to normal operation.
To return to the normal selective squelch codes, select “DEFAULT” in this mode. As 
previously described, the normal codes are also automatically reselected whenever 
radio power is cycled or a talk-around channel is selected.
5.5
Penalty Timer
A penalty timer may be programmed on conventional systems to prevent transmissions for 
the programmed time after the time-out timer disables the transmitter (see Section 4.2). 
The penalty timer can be programmed for the same times as the time-out timer, and timing 
starts when the PTT switch is released. If the PTT switch is pressed during the penalty 
time, the time-out indication occurs again and the transmitter remains disabled. When the 
penalty timer expires, a beep sounds and the transmitter can then be keyed.