E F Johnson Company 2425770 Benutzerhandbuch

Seite von 161
2-4 
Viking Portable 600 Radio Operating Manual
Controls and Display
Certain failures encountered during radio startup are indicated by blinking of the Orange 
LED. The Type of failure is indicated by the number of times the LED blinks (1 to 10) as 
described in Table 2.2
Table 2.2 LED Startup Failure Indications
ON-OFF/Volume - Turning the knob clockwise turns power on and sets the volume level. 
Turning it counterclockwise to the detent turns power off. The minimum volume level can 
be set by programming. Soft power down can be programmed as described in Section 
3.1.3, "Standard and Soft Power Down",
 and the volume control can be disabled as 
described in Section 3.1.5, "Setting Volume Level".
Rotary Control - The rotary channel selector on top of the radio. May be set for zone 
select, channel select or none. Zone select sets the knob to cycle through the first 16 zones. 
Channel select sets the knob to cycle through the first 16 channels.
Navigation Pad - This is the up and down switches on the front of the radio. Zone select 
allows the user to cycle through all the zones in the profile. This function allows changes 
to occur as soon as the button is pressed: There is no delay. Channel select allows the user 
to cycle through all the channels in the profile. The radio will loop from the last channel to 
the first and vice versa. The radio will display unprogrammed channels located between 
other programmed channels.
Toggle Control - This three-position switch sets the toggle switch to cycle through the 
first 3 zones.
Orange LED 
Blinks
Startup Failure Indicated
Description 
Incorrect Software
Boot Loader is not the expected version
2
Bad File Format
Parameter file version doe not match radio’s 
software
3
Parms Fail
Invalid backup copy of parameters stored in SPI 
Flash device
4
Bad Band
Radio band stored in parameter file does not match 
the radio band in the tuning parameters
5
Corrupt Parms
Parameters file contains an error, although 
parameters checksum is valid
6
EEPROM Fail
Self test timed out without successful read/
verification of parameter file
7
DSP Fail
PowerPC never received Power-up message from 
the DSP
8
Cycle Power
Communication failure between DSP and back-end 
ADC on the RF Deck
9
HC08 Init Fail
HC08 was not initialized correctly and cannot be 
accessed
10
Zone Fail
Number of zones exceeds the number of zones for 
which the radio was optioned
Preliminary Draft 3/9/12