E F Johnson Company 2425M70 Benutzerhandbuch
10-3
Tones & Error Messages
Alternating Tone
• Dynamic regrouping has occurred (Section 7.12).
• Dynamic regrouping has occurred but the regrouping channel is not selected (Section
7.12).
Busy Signal
• The radio system is busy or a busy condition exists when making a telephone call.
Three Medium Pitch Tones
• A channel is available after a busy condition occurred (SMARTNET/SmartZone only).
10.2
Error Messages
The following are definitions of the various error messages that may be displayed.
Aff Failed - A group affiliation attempt has received a FAILED response from the system.
The precise reason for a FAILED response is manufacturer dependent.
The precise reason for a FAILED response is manufacturer dependent.
Aff Deny - A group affiliation attempt has received a DENIED response from the system.
The precise reason for a DENIED response is manufacturer dependent. One common
cause is that the group is disallowed on the site/RFSS that the radio is attempting to
affiliate on.
The precise reason for a DENIED response is manufacturer dependent. One common
cause is that the group is disallowed on the site/RFSS that the radio is attempting to
affiliate on.
Aff Refusd - A group affiliation attempt has received a REFUSED response from the
system. The precise reason for a REFUSED response is manufacturer dependent.
system. The precise reason for a REFUSED response is manufacturer dependent.
Answr Only - The user has attempted to initiate a private call or interconnect call and the
feature is programmed for answer only.
feature is programmed for answer only.
Attach GPS - This error indicates that the user has tried to enter GPS mode without
attaching the GPS receiver to the radio.
attaching the GPS receiver to the radio.
Bad Band - A profile/or user parameters have been downloaded with Armada that are for
a band different from the hardware of the radio.
a band different from the hardware of the radio.
Bad ESN -The ESN of the radio is not valid. This error is usually only seen in the factory
when first programming brand new logic boards.
when first programming brand new logic boards.
Draft 4/29/2014