Controls & Display
The user can set an external line by pressing the emergency button. External devices 
can trigger off of the radio’s external line. If the “Ext Emergency” Option is enabled by 
programming and the user presses the emergency button, the Aux B line on the 
accessory connect shall be set to low (0V). It remains low until the External Emergency 
Time has passed or the user exits the emergency. If the user presses emergency during 
the External Emergency Time, the timer starts over. If the user exits emergency before 
the External Emergency Time has passed, the output line returns to Vbatt. 
Speaker - An internal 16-ohm, 5-watt speaker is located behind the grille. An optional 4-
ohm, 12-watt external speaker may be used if desired. The internal speaker should be 
disabled when an external speaker is used.
2.1.2
Display
Figure 2.3 shows the front panel display.
Note
Radios are capable of displaying messages in English, French or Spanish.
Figure 2.3
Front Panel Display
Alphanumeric Display - This ten-character area of the display indicates the alias (unique 
identification) for the selected zone, channel or combined aliases, depending on which 
select mode is active. It may also indicate such things as the channel frequency, ID 
numbers, and status and error messages.
10 - Character Alphanumeric Display
Zone
Number
Status
Display
Channel
Number
MON
Operating Mode 
Symbols
Zone/Channel Select Indicators