Learn Mode Freeze Sensor Installation Instructions
Figure 1: Base release tab location
3. Place transmitter in sensor cover to protect circuit board
against static damage.
4. Secure the sensor base to mounting surface by using #6
pan head screws or #18 x 1/2” wire nails (brads). If
mounting on plaster, use the appropriate fasteners. Use
mounting on plaster, use the appropriate fasteners. Use
the slotted mounting hole for alignment. See Figure 2.
Figure 2: Mounting hole locations
5. Replace the sensor circuit board on the base. Place the
reed switch end in first, then snap the board in place at the
base release tab.
6. Do not replace the sensor cover at this time.
Programming
General guidelines for programming this divce are:
1. Set the CPU into Program Mode.
2. Trip the
device’s tamper switch. See Figure 1.
3. Replace the sensor cover.
Note: Refer to the appropriate CPU installation manual for
specific instructions for programming device into the CPU.
Testing
General guidelines for performing a Dealer Signal Strength
Test are:
1. Using the appropriate touchpad for the CPU, enter the
applicable Dealer Sensor Test code.
2. Cool thermal couple with a piece of ice in a plastic bag.
When the thermal couple reaches ~45°F, the transmitter
sends an RF signal to the CPU.
3. Note the number of beeps from the CPU. These beeps
indicate
the device’s signal strength.
4. The device resets when the surrounding temperature
reaches 55°F-60°F
Regulatory information
Manufacturer
UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943,
USA
1275 Red Fox Rd., Arden Hills, MN 55112-6943,
USA
FCC compliance
This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference that
may cause undesired operation.
Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference that
may cause undesired operation.
Changes or modifications not expressly approved
by Interlogix can void the user’s authority to
operate the equipment.
by Interlogix can void the user’s authority to
operate the equipment.
FCC ID: B4Z-561M-FREEZE
IC compliance
IC: 1175C-561FREEZE
This Class B digital apparatus complies with
Canadian ICES-003.
Canadian ICES-003.
Cet appareil numérique de la classe B est
conforme à la norme NMB-003 du Canada.
conforme à la norme NMB-003 du Canada.
Le fonctionnement est soumis aux deux
conditions suivantes : (1) cet appareil peut ne pas
provoquer d’interférences et (2) cet appareil doit
accepter toutes interférences, y compris les
interférences pouvant provoquer un
fonctionnement non désiré de l’appareil.
conditions suivantes : (1) cet appareil peut ne pas
provoquer d’interférences et (2) cet appareil doit
accepter toutes interférences, y compris les
interférences pouvant provoquer un
fonctionnement non désiré de l’appareil.
Contact information
. For
© 2014 United Technologies Corporation. Interlogix is part of
UTC Building and Industrial Systems, a unit of United
Technologies Corporation. All rights reserved.