UTC Fire & Security Americas Corporation Inc 561M-FREEZE User Manual

Page of 2
 
2  
Learn Mode Freeze Sensor Installation Instructions 
Figure 1: Base release tab location 
3.  Place transmitter in sensor cover to protect circuit board 
against static damage. 
4.  Secure the sensor base to mounting surface by using #6 
pan head screws or #18 x 1/2” wire nails (brads). If 
mounting on plaster, use the appropriate fasteners. Use 
the slotted mounting hole for alignment. See Figure 2.  
Figure 2: Mounting hole locations 
5.  Replace the sensor circuit board on the base. Place the 
reed switch end in first, then snap the board in place at the 
base release tab.  
6.  Do not replace the sensor cover at this time. 
Programming 
General guidelines for programming this divce are: 
 
1.  Set the CPU into Program Mode. 
2.  Trip the 
device’s tamper switch. See Figure 1. 
3.  Replace the sensor cover. 
Note: Refer to the appropriate CPU installation manual for 
specific instructions for programming device into the CPU. 
Testing 
General guidelines for performing a Dealer Signal Strength 
Test are: 
1.  Using the appropriate touchpad for the CPU, enter the 
applicable Dealer Sensor Test code. 
2.  Cool thermal couple with a piece of ice in a plastic bag. 
When the thermal couple reaches ~45°F, the transmitter 
sends an RF signal to the CPU. 
3.  Note the number of beeps from the CPU. These beeps 
indicate 
the device’s signal strength. 
4.  The device resets when the surrounding temperature 
reaches 55°F-60°F 
Regulatory information 
Manufacturer 
UTC Fire & Security Americas Corporation, Inc. 
1275 Red Fox Rd., Arden Hills, MN 55112-6943, 
USA 
FCC compliance 
This device complies with part 15 of the FCC 
Rules. Operation is subject to the following two 
conditions: (1) This device may not cause harmful 
interference, and (2) this device must accept any 
interference received, including interference that 
may cause undesired operation.  
Changes or modifications not expressly approved 
by Interlogix can void the user’s authority to 
operate the equipment. 
FCC ID: B4Z-561M-FREEZE 
IC compliance 
IC: 1175C-561FREEZE  
This Class B digital apparatus complies with 
Canadian ICES-003.  
Cet appareil numérique de la classe B est 
conforme à la norme NMB-003 du Canada.  
Le fonctionnement est soumis aux deux 
conditions suivantes : (1) cet appareil peut ne pas 
provoquer d’interférences et (2) cet appareil doit 
accepter toutes interférences, y compris les 
interférences pouvant provoquer un 
fonctionnement non désiré de l’appareil.  
Contact information 
For general information, see 
For 
customer/technical support, see 
  or call +1 855 286 8889. 
© 2014 United Technologies Corporation. Interlogix is part of 
UTC Building and Industrial Systems, a unit of United 
Technologies Corporation. All rights reserved.