MGL Avionics CC V16 Benutzerhandbuch
Byte 5
Length of ascii string in bytes
Byte 6
1
st
character of string
Byte 7
2
nd
character of string
ID 0x4n1
Subsequent menu packet(s), length 2 to 8 bytes
Byte 0
Message type – 1,2,3,4,5 (maximum 31 characters in string, 7 per packet)
Byte 1-7
Remaining characters of string to a maximum of 7 characters.
Technical string
This message is sent on condition to convey further information. It is only used during
technical work using dedicated diagnostics equipment.
technical work using dedicated diagnostics equipment.
ID 0x4n2
Subsequent menu packet(s), length 2 to 8 bytes
Byte 0
Message type – 0
Byte 1
Length of string in bytes
Byte 2-7
Up to 6 characters of string
ID 0x4n2
Subsequent technical text packet(s), length 2 to 8 bytes
Byte 0
Message type – 1-9 (maximum 63 characters in string, 7 per packet)
Byte 1-7
Remaining characters of string to a maximum of 7 characters.
Messages to the V16
V16 controllers use the assigned CAN ID 0x48n where “n” is a message type identifier.
Multiple control heads will use the SAME ID.
Multiple control heads will use the SAME ID.
ID 0x480
Length variable (minimum 1 byte)
Byte 0
Command ID
Byte 1-7
Optional data for command
Note: the V16 checks the length of a received CAN packet and will only accept packets that
have the correct length for a given command. Do not pad a packet. Send it at the correct
length.
have the correct length for a given command. Do not pad a packet. Send it at the correct
length.
Command Length Function
0
0
4
Set active frequency (three bytes, LSB first)
1
4
Set standby frequency (three bytes, LSB first)