MGL Avionics CC V16 사용자 설명서

다운로드
페이지 13
Byte 5
Length of ascii string in bytes
Byte 6
1
st
 character of string
Byte 7
2
nd
 character of string
ID 0x4n1
Subsequent menu packet(s), length 2 to 8 bytes
Byte 0
Message type – 1,2,3,4,5 (maximum 31 characters in string, 7 per packet)
Byte 1-7
Remaining characters of string to a maximum of 7 characters.
Technical string
This message is sent on condition to convey further information. It is only used during 
technical work using dedicated diagnostics equipment.
ID 0x4n2
Subsequent menu packet(s), length 2 to 8 bytes
Byte 0
Message type – 0
Byte 1
Length of string in bytes
Byte 2-7
Up to 6 characters of string
ID 0x4n2
Subsequent technical text packet(s), length 2 to 8 bytes
Byte 0
Message type – 1-9 (maximum 63 characters in string, 7 per packet)
Byte 1-7
Remaining characters of string to a maximum of 7 characters.
Messages to the V16
V16 controllers use the assigned CAN ID 0x48n where “n” is a message type identifier. 
Multiple control heads will use the SAME ID.
ID 0x480
Length variable (minimum 1 byte)
Byte 0
Command ID
Byte 1-7
Optional data for command
Note: the V16 checks the length of a received CAN packet and will only accept packets that 
have the correct length for a given command. Do not pad a packet. Send it at the correct 
length.
Command Length Function
0
4
Set active frequency (three bytes, LSB first)
1
4
Set standby frequency (three bytes, LSB first)