Panasonic Corporation of North America 9TAK-SAP14 Benutzerhandbuch

Seite von 25
Functions and settings
 
 
●  E2 CNT function 
These functions are available when K-SAP14 is used. When E2 is controlled with the microphone, control signals are provided 
from the E2 CNT terminal of this unit. Selection between E2 is made at the microphone side. 
E2: Default setting is Open. 
Press the both sides [E2] button of the microphone for 2 seconds or more or press the alert button to select the close state. 
 
 
 
 
●  E2 ACK function 
When make signal inputs are provided to E2 ACK of the control terminals during E2 operation, the MIC1 or MIC2 LED indicator of 
this unit, MIC1 or MIC2 turns from red to green to indicate that the E2 ACK signal is received. 
When the E2 control input has not been provided from the microphone for 3 minutes after turning off the power of the microphone, 
the E2 state ends, the MIC1 or MIC2 LED indicator indicates the receiving state, and the operation LED turns from red to green to 
indicate the operating state.