Taiwan Biotronic Technology Inc. 48525332323030 Benutzerhandbuch
LifeVisa
W
IRELESS
H
EART
R
ATE
T
RANSMITTER
HRS‐2200 User Manual
COMPONENTS
Heart Rate Transmitter
Elastic Strap
O-Ring
Battery Cover
Screw x 4pcs
Magnetic Key
3V CR2032
Lithium Battery
Lithium Battery
2.4GHz
TRANSMITTER BATTERY INSTALLMENT
This Transmitter includes a 3V CR2032 lithium battery.
Please follow below steps to install the battery.
Step 1.
Insert the battery (CR2032) with the positive (+) side up.
Please follow below steps to install the battery.
Step 1.
Insert the battery (CR2032) with the positive (+) side up.
☆
Make sure the battery is hooked by the contact spring.
Step 2.
Put on the O-Ring in the groove to ensure water resistance.
Put on the O-Ring in the groove to ensure water resistance.
☆
Make sure to place the O-Ring properly in order to prevent battery
composition from being spoiled by sweat and moisture.
Step 3.
Place Battery Cover with convex face up.
Step 4.
Tighten 4 screws properly.
Step 3.
Place Battery Cover with convex face up.
Step 4.
Tighten 4 screws properly.
Thank you for purchasing LifeVisa products. This manual contains
information required to use the Heart Rate Transmitter. Please read this
manual thoroughly before you use the Heart Rate Transmitter.
information required to use the Heart Rate Transmitter. Please read this
manual thoroughly before you use the Heart Rate Transmitter.
1
3. Adjust the strap length to fit around your chest
snugly and comfortably, just below the pectoral
muscles.
TROUBLESHOOTING AND CARE
Troubleshooting of the Transmitter
●
If you are not getting a good connection to the host, please
(a) Check the Transmitter and make sure it's not worn too high or too low
on the chest. Adjust the position of the Transmitter on the chest to
see if satisfactory connection has been achieved.
(b) Apply some ECG gel on the electrodes to get better performance.
(c) Check if the battery is installed properly or change a new battery.
(d) Repeat HOST CONNECTION section.
on the chest. Adjust the position of the Transmitter on the chest to
see if satisfactory connection has been achieved.
(b) Apply some ECG gel on the electrodes to get better performance.
(c) Check if the battery is installed properly or change a new battery.
(d) Repeat HOST CONNECTION section.
●
The Transmitter will not detect heart rate when operated under water.
●
The effective range of the whole system is 10 meters. If the host is
away by a greater distance than this, it might not receive a heart rate
signal.
signal.
Care of the Heart Rate Transmitter
●
●
After every use, you should clean the electrodes in warm fresh water
and dry with a dry cloth.
●
●
DO NOT store the Transmitter wet; it must be stored in a cool and dry
place, and kept out of extremely cold and hot.
●
●
The Transmitter should be stored flat rather than folded and should
never be bent or stretched, as this may damage the electrodes.
●
●
Never lay the Transmitter on a metal surface or near magnet.
●
Avoid the Transmitter from direct exposure to sunlight.
●
Electrodes and gel should never be applied over broken skin.
●
Trim (don't shave) your body hair where electrodes are going to be put.
●
Clean skin before and after wearing the Transmitter.
4. Check that the wet electrode areas are
firmly against your skin and that the logo
of the Transmitter is in a central, upright
position.
firmly against your skin and that the logo
of the Transmitter is in a central, upright
position.
4
HOW TO WEAR THE TRANSMITTER
3. Wait for connection.
4. The host should begin to display a reading, showing the connection
has been done and you can start your workouts.
has been done and you can start your workouts.
NOTE:
☆
This step only has to be done at the first time of use with the same
Transmitter and host. Afterwards, even changing battery, you don't
need to reconnect to the host.
need to reconnect to the host.
☆
See TROUBLESHOOTING AND CARE section if you are experiencing
connection issues.
The Heart Rate Transmitter consists of two conductive electrodes. The
electrodes sense the heart beat.
electrodes sense the heart beat.
1. For best performance, before wearing the Transmitter, please moisten
the electrodes on the back of the Transmitter using clean tap water or
ECG gel. This makes it easier for the electrodes to detect the electrical
signal.
the electrodes on the back of the Transmitter using clean tap water or
ECG gel. This makes it easier for the electrodes to detect the electrical
signal.
2. Attach one side of the strap to the Transmitter. Then wear it over your
chest and meet the strap with the Transmitter at the other side.
chest and meet the strap with the Transmitter at the other side.
ELECTRODES
3
Step 1.
Step 2.
Step 3.
Step 4.
2
☆
The effective distance/range is within 10 meters. Be sure no other
devices are within this distance making the same approach.
HOST CONNECTION
This Transmitter must be recognized to the host before being used for the first
time. Please follow below instructions to complete the connection.
time. Please follow below instructions to complete the connection.
1. Turn on the host and enter connection
mode. The host will wait the signal
for 1 minute. If not receiving the
signal, the host will exist the
connection mode automatically.
mode. The host will wait the signal
for 1 minute. If not receiving the
signal, the host will exist the
connection mode automatically.
2. Use Magnetic Key to startup the
host connection function in the
Heart Rate Transmitter by sliding
on the top of Transmitter.
host connection function in the
Heart Rate Transmitter by sliding
on the top of Transmitter.
NOTE:
☆
Open the battery cover only when changing the battery to ensure a
long life, and make sure the O-Ring is not damaged, in which case
you should replace it with a new one.
you should replace it with a new one.
☆
Keep battery away from children. If swallowed, contact a physician
at once. B
atteries
should be
disposed of in compliance with applicable
laws and regulations
.
Connection
done!!!