MRC-565 Packet Data Radio Operations and Maintenance 
 
4  INSTALLATION 
4.1  Cable Connections 
 
There are a maximum of seven cable connections to be made to the MRC-565 as shown in 
Figure 5.   
 
 
 
 
Figure 5. MRC-565 Connector Panel 
 
4.1.1  DC Power 
 
The MRC-565 requires a power source that can deliver up to 20 amps of pulsed power (100 
msec) from a +12 V
DC
 to +16V
DC
 power source.   
 
The 20 amp current draw will cause a voltage drop to occur at the transmitter input, resulting in 
reduced transmit power, unless the power cable to the source is sized appropriately.  MRC 
recommends using two #16 AWG wires for both the power and ground and a cable length that 
does not exceed 10 feet.  If a longer cable is required, use #14 AWG.  MRC provides a standard