• Although the UPC is weather-resistant, the housing and UPC should be sheltered from rain or a
canopy should be provided.
5.2.3.2 Tools
For this guide, we assume that the cabinet has been prepared with the appropriate cut-out prior to
installation. Please see §5 UPC Cutout for details.
The only tool required for installation is a 3mm hex (Allen) key. The shaft of the key should be at least
100mm long for ease of use.
5.2.3.3 Method
1. Check that the cabinet cut-out is free of burrs and ripples and that all the mounting holes are clear.
2. Check the UPC packaging for signs of tampering. If the factory seals are not intact DO NOT install
the UPC.
3. Unpack the UPC carefully. Again check for signs of tampering, both with the UPC and with its
rubber gasket.
4. Check that the rubber gasket is placed the correct way up, flat against the rear of the housing:
Fig. 5.10: Gasket Upside-down
Fig. 5.11: Gasket Right Way Up
5. Place the housing containing the UPC from the outside of the cabinet into the cabinet cut-out.
Check that the housing sits flat against the cabinet and that the gasket is not rippled or folded
anywhere.