Fig. 5.12: Mounting Holes
6. Insert mounting screws in the top and bottom centre holes of the UPC but do not tighten them.
7. Insert the remaining six screws, three along each side.
8. Ensure the housing is aligned neatly in the cutout, then tighten all eight mounting screws.
This will arm the eight removal-tamper sensors (coloured red in the figure, see §5 Housing
Removal-tampers).
These tampers will become active when the UPC is promoted from its
removal-tampered state to normal operating mode.
Chapter 5. Appendices
34