Vital Home Systems LLC 1060 Benutzerhandbuch

Seite von 13
P a g e
 | 
 
 
© 2015 - 2016 Vital Home Systems, LLC 
The Wireless Control Panel LED will also flash 
ON, enabling the person testing the range from 
afar to see the condition in case the beep 
cannot be heard.  
NOTE: 
  Once a sensor has been successfully 
Learned-In, the Wireless Control Panel LED 
will stay lit for another 60 seconds to allow 
you to Learn-In the next one. 
  Once in Range-Test Mode, if a key is not 
pressed for 30 minutes, the Wireless 
Control Panel will sound five (5) quick-
beeps then automatically exit Range-Test 
Mode and return to Program Mode. 
  You may exit Range-Test Mode to return to 
Programming Mode anytime by pressing 
“CLR” key. 
  To exit Programming Mode and return to 
Normal Mode, press “CLR” key. 
  To enter Range-Test Mode, return to  
Step 1. 
Exit Programming Mode 
Press “CLR” key to exit the Programming Mode and 
return to Normal Mode. 
Reset Wireless Control Panel to Default 
Settings 
Step 1: Remove all power sources, including AC 
power adaptor and battery. (To remove the 
battery remove the 4 black feet and unscrew 
the 4 case screws.  Be careful not to over 
tighten the screws when putting back together 
so as not to strip the screw holes. Unplug the 
battery from the PC board). 
Step 2: With the panel apart keeping the “CLR” key 
pressed, plug in the AC power adaptor. A long 
one-second beep will emit indicating that the 
Panel has been successfully reset to Default 
Settings. 
Step 3: Plug the battery back in and close the case 
carefully not to over tighten the screws. 
NOTE: 
Under Factory Default Setting – 
 
PIN code is set as “0000” 
 
Wireless Control Panel is cleared of all 
telephone numbers. 
 
Wireless Control Panel is cleared of all 
sensor devices. 
Operation  
IMPORTANT NOTICE TO USER:  The installation of 
any  water  detection  or  automatic  water  shut  off 
system does NOT guarantee water will be detected 
on  all  occasions  or  circumstances.    Due  to  the 
variety  of  environments  the  system  can  be 
installed,  how  it  is  maintained  and  types  of 
installation,  Vital  Home  Systems  does  NOT 
guarantee  or  warrant  against  water  or  property 
damage  as  a  result  of  or/with  the  use  of  this 
system. 
Upon receiving the signal from the Water Sensors or 
VC100, the Wireless Control Panel will flash the 
Wireless Control Panel POWER LED and play the 
appropriate message for specific event and time 
period. 
NOTE: 
  For VC-100 / AWS/TWS, it will play 
appropriate voice message locally for 15 
seconds before dialing out.  
  If two or more sensors are triggered one 
after another, the corresponding messages 
will be played in rotation. 
  After the Audio is played the SMS messages 
will begin to be sent from the Wireless 
Control Panel 
  If no telephone number is stored, the 
Wireless Control Panel will not send SMS 
reports  
  When two or more telephone numbers are 
stored, the Wireless Control Panel will send 
SMS reports in accordance to the Priority 
Order number.  
  If prior to or during voice alarm playback, 
the Wireless Control Panel receives a 
disarm signal via SMS or when its “ACK” key 
is pressed, the Wireless Control Panel 
Power LED stops blinking and the Wireless 
Control Panel stops the reporting. 
  The Wireless Control Panel phone numbers 
entered are to be for cell phone numbers 
only for SMS receipt 
Fault Situations 
The Yellow LED (Fault LED) will flash ON if the VHS-
Wireless Control Panel or any of the Learned 
devices have a fault such as are disconnected or in a 
continual low-battery status.   
  The Yellow LED will turn OFF automatically 
once all of the faulty conditions are 
restored, or faulty devices are removed via 