Vital Home Systems LLC AWS-01 Benutzerhandbuch

Seite von 8
P a g e
 | 
Copyright Vital Home Systems, LLC
 
 
 
© 2015 Vital Home Systems 
 
Identifying Parts on the VHS AWS-01 
 
1.  AWS-01 Water Sensor- This is the water sensor 
device to be paired with a control panel such as the 
Vital Home Systems 1050, 1060 4G or directly with 
the VC100. 
2.  Test and Pairing Button– Push this button to test 
the water sensor with a beep or push this button to 
when directed by the Vital Home Systems Control 
Panel PC Software.  
3.  Mounting Screws Holes 
4.  3V CR2450 lithium battery 
5.  Water Detection Probes- These two probes sit less 
than 1 millimeter off a hard surface.  SEE WATER 
SENSOR PLACEMENT BEFORE DEPLOYING WATER 
SENSORS.  
6.  Optional External Water Probe– 6 foot External 
Probe to monitor remote places such as under 
appliances or inside walls.  Probe jack installs into 
side of AWS-01. 
7.  AWS Indent to Open Case – Use a Coin or other 
non-shape object to pry open case on left side. 
AWS-01 Setup 
IMPORTANT NOTE! 
Only use parts and devices supplied by Vital Home Systems with the AWS-01. Only use Vital Home Systems 
supplied batteries for the AWS-01.  Installing or attaching devices not supplied by Vital Home Systems, may cause  AWS-01 
and system failure and damage as a result.  All parts and devices are designed to work specifically with the Vital Home Systems. 
Any devices installed or attached to the  AWS-01 from a third party, even if they have the same part number, immediately 
voids Vital Home Systems Limited Warranty and obligations.
 
Step 1.  Install batteries – Remove any protective film from the CR2450 3V battery.  To open sensor, use 
a coin or other non-sharp device to pry the top cover open from the indent on the left side of the sensor.  
Insert  coin  cell  CR  2450 lithium  battery  at  an  angle  with  the  positive  (+)  side  up.  Leave  cover  off  for 
pairing 
STEP 2. Pair the AWS-01 to the 1050 /1060 4G or VC100 – 
All 
programming of the AWS-01 water 
sensor may be done via the 1050 or 1060 Control Panel with the Vital Home Systems PC software.  The 
software may be downloaded from Vital Home Systems Website at: 
 
You must register your 1050/1060, AWS-01 and VC100 (if purchased) on the Vital Home Systems Website 
to download the software.  The Software is written only for Windows version 7 through Vista.  Download 
and install the software to your Windows Desktop prior to plugging the 1050/1060 USB cable into the 
computer and the 1050 Control Panel. To pair the AWS-01 directly to the VC100, please contact Vital 
Home Systems.