Identifying Parts on the VHS AWS-01
1. AWS-01 Water Sensor- This is the water sensor
device to be paired with a control panel such as the
Vital Home Systems 1050, 1060 4G or directly with
the VC100.
Vital Home Systems 1050, 1060 4G or directly with
the VC100.
2. Test and Pairing Button– Push this button to test
the water sensor with a beep or push this button to
when directed by the Vital Home Systems Control
Panel PC Software.
when directed by the Vital Home Systems Control
Panel PC Software.
3. Mounting Screws Holes
4. 3V CR2450 lithium battery
5. Water Detection Probes- These two probes sit less
than 1 millimeter off a hard surface. SEE WATER
SENSOR PLACEMENT BEFORE DEPLOYING WATER
SENSORS.
SENSOR PLACEMENT BEFORE DEPLOYING WATER
SENSORS.
6. Optional External Water Probe– 6 foot External
Probe to monitor remote places such as under
appliances or inside walls. Probe jack installs into
side of AWS-01.
appliances or inside walls. Probe jack installs into
side of AWS-01.
7. AWS Indent to Open Case – Use a Coin or other
non-shape object to pry open case on left side.
AWS-01 Setup
IMPORTANT NOTE!
Only use parts and devices supplied by Vital Home Systems with the AWS-01. Only use Vital Home Systems
supplied batteries for the AWS-01. Installing or attaching devices not supplied by Vital Home Systems, may cause AWS-01
and system failure and damage as a result. All parts and devices are designed to work specifically with the Vital Home Systems.
Any devices installed or attached to the AWS-01 from a third party, even if they have the same part number, immediately
voids Vital Home Systems Limited Warranty and obligations.
and system failure and damage as a result. All parts and devices are designed to work specifically with the Vital Home Systems.
Any devices installed or attached to the AWS-01 from a third party, even if they have the same part number, immediately
voids Vital Home Systems Limited Warranty and obligations.
Step 1. Install batteries – Remove any protective film from the CR2450 3V battery. To open sensor, use
a coin or other non-sharp device to pry the top cover open from the indent on the left side of the sensor.
Insert coin cell CR 2450 lithium battery at an angle with the positive (+) side up. Leave cover off for
pairing
a coin or other non-sharp device to pry the top cover open from the indent on the left side of the sensor.
Insert coin cell CR 2450 lithium battery at an angle with the positive (+) side up. Leave cover off for
pairing
STEP 2. Pair the AWS-01 to the 1050 /1060 4G or VC100 –
All
programming of the AWS-01 water
sensor may be done via the 1050 or 1060 Control Panel with the Vital Home Systems PC software. The
software may be downloaded from Vital Home Systems Website at:
software may be downloaded from Vital Home Systems Website at:
You must register your 1050/1060, AWS-01 and VC100 (if purchased) on the Vital Home Systems Website
to download the software. The Software is written only for Windows version 7 through Vista. Download
and install the software to your Windows Desktop prior to plugging the 1050/1060 USB cable into the
computer and the 1050 Control Panel. To pair the AWS-01 directly to the VC100, please contact Vital
Home Systems.