AWS-01 Operation 
IMPORTANT NOTICE  TO  USER:   The installation of  any water detection or  automatic water shut  off 
system does NOT guarantee water will be detected on all occasions or circumstances.  Due to the variety 
of environments the system can be installed, how it is maintained and types of installation, Vital Home 
Systems does NOT guarantee or warrant against
 water or property damage as a result of or/with the 
use of this system.
 
Normal Operation 
The  AWS-01  will  only  detect  puddling  water  when  it  contact  the  water  probes.    It  does  not  detect 
humidity.  Water  MUST  contact  the  probes  to  actually  report  water.  If  the  control  panel  loses 
connection with the AWS-01 after 12 hours it will send a “Fault Detected” report with the sensor ID to 
the user.  The AWS-01 will also send a report on the condition of a low battery. When water is detected 
and contacts the probe, the AWS-01 sends a “Leak Detected” report with the Sensor Zone ID. The AWS-
01 will also make a beeping noise to alert the user.  If the sensor is picked up and loses contact with the 
water or the alarm clears the AWS-01 will send an “Alarm Ended” report to the control panel. If a VC100 
valve controller is paired with the 1050/1060 control panel and a specific AWS-01, it will be commanded 
to close upon the detection of water and will not reopen until the VC100 is commanded to open on the 
VC100, the 1050/1060 or remotely. 
External Water Probe 
To install the External water probe.  Plug the jack into the right side of the AWS-01.  The AWS-01 will 
now sense water in two locations at the same time.  If possible affix the external probe to the surface to 
be monitored with 2 screws. You may also use double stick tape BUT only use thin film tape that does 
not raise the external probes more than 2 millimetres off the surface. 
DO NOT USE FOAM DOUBLE STICK 
TAPE this increases the distance from the probe to the surface of the water you are trying to detect.  
Accidental disconnect of the external probe will disable water detection by the external probe. 
How to Avoid False Alarms 
  Place the AWS-01 and probe in a location that will not accidentally contact water or come in 
contact with water while washing a floor.   
  Avoid placing the AWS-01 or probe on a conductive surface or carpeting 
  Avoid placing the AWS-01 or probe in a dusty environment 
  Spider webs may also cause false alarms 
  In the event of a false alarm.  Wipe the probes with a clean dry cloth open the cover and 
inspect for water damage.  If required allow to dry and insert a fresh battery to see if the false 
alarm clears. 
Low Battery Condition 
Once a “Low Battery” report is received. Replace the batteries in the AWS-01 as soon as possible, push 
the button on the sensor after installation.  NOTE: If the “Low Battery” report is cleared on the control 
panel the user will not receive another low battery alarm. Do not clear the alarm on the control panel 
until the AWS-01 batteries have been replaced.