3.7 Lightning/Surge Protection
Vubiq Networks, Inc. strongly suggests that installer use a surge suppressing lightning arrestor on any
copper cable that will be connected to the HaulPass V10g. An L-Com Lightning Arrestor is shipped with
the terminal for this purpose and will provide protection for the PoE++ P1 port. If the user chooses to use
copper cable that will be connected to the HaulPass V10g. An L-Com Lightning Arrestor is shipped with
the terminal for this purpose and will provide protection for the PoE++ P1 port. If the user chooses to use
the 48VDC power port, the P2 port, or copper on the 1000Base-X or 10000Base-X ports additional lightning
arrestors should be installed for those ports.
arrestors should be installed for those ports.
3.8 Grounding
A ground wire must be connected between the ground lug and the metal mounting mast. Verify that the
metal mast is electrically connected to the structure ground. Improper structure-to-earth grounding can
result in electromagnetic interference and susceptibility to electrical discharge. Incorrect grounding will void
metal mast is electrically connected to the structure ground. Improper structure-to-earth grounding can
result in electromagnetic interference and susceptibility to electrical discharge. Incorrect grounding will void
the warranty of the HaulPass V10g. In addition, Vubiq strongly recommends the use of outdoor surge/lightning
protectors.