Vubiq Networks Inc. V10G-L Benutzerhandbuch

Seite von 69
 
60  
Vubiq HaulPass V10g User Manual 
 
 
  
 
              © 2018 Vubiq Networks, Inc. All Rights Reserved 
MIB: vubiqRfFpgaVersion 
OID: .1.3.6.1.4.1.46330.2.2.1.21.0 (OctetString) 
temp (Board temperature setting) 
The temp parameter shows the current operating temperature of the Vubiq HaulPass V10g. 
The CLI command: 
rf board temp 

The Web GUI view: 
 
MIB:  vubiqRfBoardTemp 
OID:  .1.3.6.1.4.1.46330.2.2.1.15.0 (Integer) 
uptime (Board uptime status) 
The uptime measures the amount of uptime measured in seconds that RF Subsystem has this power cycle. 
The CLI command: 
rf board uptime 
5421 
The Web GIU: 
 
MIB:  vubiqRfBoardUpTime 
OID:  .1.3.6.1.4.1.46330.2.2.1.19.0 (Integer) 
10.2  rf rx (Rx Module Command) 
agc-sensitivity (Rx AGC sensitivity setting) 
The agc-sensitivity command allows the user to read and write the receive agc-sensitivity of the RF receive module. 
CLI example: 
rf rx agc-sensitivity 16 
rf rx agc-sensitivity 
16 
MIB: vubiqRfRxAgcSensitivity 
OID: .1.3.6.1.4.1.46330.2.2.1.14.0 (Integer)