600840-000031 Stratus ESG Installation Instructions 
Rev. 1.1 
Last Revised: January 6, 2016 
 
Page 19 of 42 
2. Installing Stratus ESG 
2.1. 
Unpacking/inspection requirements 
When unpacking Stratus ESG, visually inspect for any damage to the unit or missing 
components. If damage or missing parts are present, contact Appareo. 
2.2. 
Limitations for installation 
This article meets the minimum performance and quality control standards required by a 
technical standard order (TSO). If you are installing this article on or in a specific type or class of 
aircraft, you must obtain separate approval for installation. 
The following limitations should be taken into consideration when installing Stratus ESG. 
Aircraft 
Stratus ESG may not be acceptable for installation on all aircraft makes and models. 
Cooling air 
Stratus ESG does not have an air cooling duct. Do not install Stratus ESG near a heat source. 
An alternate method of cooling is required if the unit must be installed near a heat source. 
2.3. 
Backplate assembly and rack installation 
Refer to Stratus ESG Installation and Wiring Drawings (601837-000024) to assemble the 
mounting rack with the hardware specified in Table 10. Mount the rack to the aircraft using the 
six holes on the side of the rack with the hardware specified in Table 11. 
Refer to Section 1.8 for dimensions and weight information. 
NOTE: For an optimal fit, mounting brackets may be required, but are not supplied. If additional 
brackets are needed, they should be fabricated for each individual installation. 
NOTE: Assure that the unit is supported in the back. This may require additional support.