Appareo Systems LLC 1505005 Benutzerhandbuch

Seite von 42
600840-000031 Stratus ESG Installation Instructions 
Rev. 1.1 
Last Revised: January 6, 2016 
 
Page 20 of 42 
2.4. 
Unit installation 
 
1. 
Adjust the locking mechanism on Stratus ESG using a 3/32 hex wrench so that 
the front lobe is in a vertical position. Insert the unit into the mounting rack until 
the faceplate is flush with the front end of the rack. 
2. 
Tighten the locking mechanism clockwise with the 3/32 hex wrench until it is tight 
and the connectors have mated. Do not overtighten. If the mechanism will not 
tighten, verify that Stratus ESG is properly seated in the rack. 
2.5. 
Cleaning 
Use a dry cloth to clean Stratus ESG. If necessary, a lightly damp cloth with a solution of mild 
detergent can be used. Do not use cleaners containing ammonia, acetone, or other strong acids 
or bases to clean the Stratus ESG display or faceplate. 
2.6. 
Placard installation 
Placards should be installed in accordance with AC 43.13-2B, Chapter 2, Section 207, Sub-
Section f., Paragraph (4). 
3. Cabling and wiring 
This section describes cabling and wiring specifications, pin-out information, and antenna 
connection procedures. 
CAUTION: Stratus ESG must be OFF during wiring to avoid damaging the device. 
3.1. 
Cabling and wiring specifications 
Wiring must be installed in accordance with FAA AC 43.13-1B and AC 43.13-2B and will be 
supplied by the aircraft installer. Wiring will be 20-24 gauge; see Stratus ESG Installation and 
Wiring Drawings (601837-000024) for exact specifications. The wire length and routing will vary 
by installation.