1. 
Turn Stratus ESG off and enter into configuration mode on Stratus ESG (while 
holding the FUNC key, press and release the PWR key.).  
2. 
Press FUNC or the arrow keys to advance to the external input diagnostics 
screen. The screen displays the real-time state of the external standby, external 
IDENT, and squat switch inputs. 
3. 
Activate and deactivate each discrete input and verify that the proper state is 
reflected on the display. 
  External standby: Ground each transponder
’s external standby pin and verify 
that the state is “inactive.” 
  External IDENT: Activate the external switch and verify that the state is 
“active.” 
  Squat switch: Activate the squat switch and verify that the correct state is 
shown. 
5.3. 
Analog inputs 
1. 
Enter into configuration mode on Stratus ESG. 
2. 
Press FUNC or the arrow keys to advance to the analog input diagnostics 
screen. The screen displays the real-time values read from the lighting bus and 
ambient light sensor. 
3. 
Block the ambient lighting sensor input. Verify that the signal percentage drops. 
 
Figure 2: Ambient light sensor location 
4. 
Shine a light on the ambient light sensor. Verify that the signal percentage 
increases. 
5. 
If you are using the 14V or 28V lighting bus: Adjust the lighting bus input to 
minimum. Verify that the displayed value is 0%. 
6. 
If you are using the 14V or 28V lighting bus: Adjust the lighting bus input to 
maximum. Verify that the displayed value is 100%.