11.2 Replacing the batteries of the HydrINS 2 / HydrINS 2 Mini flow meter 
Apply the following procedure to replace the batteries in the head of the HydrINS 2 / HydrINS 2 Mini 
flow meter:  
1 – Open the head of the flow meter (see Para. 8.3). 
2 – Disconnect the used battery and connect the new one. 
3  –  In  Winfluid,  click  the  HydrINS  II  or  Mini  HydrINS  input  channel.  In  the  Sensor  tab,  click 
Properties, and then Advanced. In the Maintenance tab, select the boxes for Batteries 1 and 2 in the 
head,  and  then  confirm  by  clicking  OK.  The  battery  level  will  then  be  reinitialised  during  probe 
programming.  
4 – Click "Sensor" and then "program". 
 
Figure 43: Reinitialisation of the battery levels in HydrINS 2 in Mode 1 in Winfluid 
11.3 Replacing the display batteries 
1 – Open the upper cover of the Display. 
2 – Remove the used battery and insert the new battery. 
3 – Close the cover of the Display. 
4  –  In  Winfluid,  click  the  HydrINS  II  or  Mini  HydrINS  input  channel.  In  the  Sensor  tab,  click 
Properties, and then Advanced. In the Maintenance tab, select the boxes for Battery 2, indicate the 
capacity  in  Ah  of  the  new  battery,  and  then  confirm  by  clicking  OK.  The  battery  level will  then  be 
reinitialised during probe programming.