Wavetec FZCO WT-AH Benutzerhandbuch

Seite von 36
QC Guide of Active Hub  
 
 
Jul. 13 
14 
To test Active Hub on Display Network, Change its DIP switch position to “Display” as shown below. 
 
1.  Test Procedure of Testing Active Hub on Display Networks:        
 
When the TSU is connected with the Network Scanner PCB and the 12V DC adapter is inserted in the DC JACK of 
Network Scanner PCB, TSU will turn “ON”. Following screen will appear, 
 
After few seconds following message will appear: 
 
Then Press buttons 3 &4 together for atleast 5 seconds or until following message is appeared. 
 
Press button “Next”, following message will appear: 
Welcome to TSU setup 
 
1)TSU for eQ prime 
2)TSU for eQ linux 
 
Hit Next for options 
 
 
WAVETEC 
eQ 
 
TSU ID = 001 
 
 
Ver : TSU 06-1-06 
 
Use opposite 
configuration as Dip 
switch is now bottom 
actuated.