Zone Response Type Definitions 
 
Type 07 
24-hour  
Audible 
Alarm 
 
Zone type 07 is usually assigned to a zone containing an Emergency 
button (audible emergency). 
Zone Characteristics: 
•  Sends a report to the central station, and provides alarm sounds 
externally and at the keypad. 
Type 08 
24-hour  
Auxiliary Alarm 
Zone type 08 is usually assigned to a zone containing a button for use 
in personal emergencies or to a zone containing monitoring devices 
(i.e.: water or temperature sensors, etc.). 
Zone Characteristics: 
•  Sends a report to the central station and provides an alarm sound at 
the keypad. (No bell output is provided and there is no keypad 
timeout.)  
5806/5807/5808
01000-020-V0
 
Type 09 
Supervised 
Fire 
Zone type 09 can be assigned to any wireless zone used as a 
fire zone. This zone type is always active and cannot be 
bypassed. 
Zone Characteristics
•  Bell output will pulse when this zone type is alarmed. 
Type 10 
Interior w/Delay 
Zone type 10 is bypassed when the panel is armed in the STAY or STAY
NO DELAY mode. 
Zone Characteristics
•  Entry delay #1 (with programmed entry time) when armed in the 
AWAY mode.  
•  Entry delay begins whenever sensors in this zone are violated, 
regardless of whether an entry/exit delay zone was tripped first.  
•  No entry delay when armed in the AWAY NO DELAY mode. 
•  Exit delay regardless of the arming mode selected.  
Type 20 
Arm–Stay 
Zone type 20 is a special-purpose zone type used with 5800 Series 
wireless pushbutton units. 
Zone Characteristics: 
•  Exit delay regardless of the arming mode selected. 
•  System is armed in the STAY mode when the zone is activated.  
•  Zone number is sent to the central station as a user number when 
arming or disarming. 
Type 21 
Arm–Away 
Zone type 21 is a special-purpose zone type used with 5800 Series 
wireless pushbutton units. 
Zone Characteristics:  
•  System is armed in the AWAY mode when the zone is activated.  
•  Zone number is sent to the central station as a user number when 
arming or disarming. 
Type 22 
Disarm 
Zone type 22 is a special-purpose zone type used with 5800 series 
wireless pushbutton. 
Zone Characteristics:  
•  Disarms the system when the zone is activated. 
Type 23 
No Alarm Response 
Zone type 23 can be used on a zone when a Powerline Carrier Device 
(e.g., X-10) action is desired, but with no accompanying alarm (e.g., 
front door light).  
Type 24 
Silent Burglary 
Zone type 24 is usually assigned sensors or contacts on exterior doors 
and windows where bells and/or sirens are NOT desired. 
Zone Characteristics
•  Instant alarm, with NO audible indication when is armed in the 
AWAY, STAY, STAY NO DELAY, or AWAY NO DELAY mode.  
•  Report sent to the central station. 
Note:   Keypad beeps if the zone is faulted when system is disarmed and Chime 
mode is on. 