Honeywell ADEMCO LYNXR Series Benutzerhandbuch

Seite von 72
 
–5– 
Mounting the Control 
 
Wall Mounting 
The illustration below shows the front assembly separated from the back plate. 
 
!  
DO NOT disconnect the ribbon cable from the terminal strip board. Disconnect the cable only from the 
front assembly board.  
Certain features differ between the LYNXR/LYNXR24 and the LYNXR-EN models. Verify the specific model 
being installed prior to programming the system.
 
 
DISCONNECT 
THIS END ONLY!
01009-003-V0
MXXXX K5108
RED WIRE
MARKING
16
1
LOCKING TABS
PC BOARD
PART NUMBER
LOCATION
PC BOARD
PART NUMBER
LOCATION
 
 
 
Desktop Mounting 
If desired, an optional mounting base (model LYNX-DM, purchased separately) allows the LYNXR-Series controls to be 
used on a desktop.  
 
ADD
ESCAPE
DELETE
SELECT
AWAY
OFF
STAY
AUX
01009-004-V1
WIRE ENTRY
KNOCKOUT
(1 of 3)
 
1.  Separate the front assembly from the 
back plate by pressing on the two 
locking tabs at the top of the unit. 
 
2. Carefully disconnect the ribbon cable 
from the front assembly, leaving the 
ribbon cable connected to the 
terminal block PC board
. The back 
plate contains the terminal block for 
making wiring connections. 
 
3.  Mount the back plate to a sturdy wall, 
feeding the field wiring through the 
appropriate openings in the back 
plate. 
 
4. After wiring connections are made, 
carefully reconnect the ribbon cable to 
the front assembly PC board 
connector (properly aligning the red 
wire). 
 
5.  Before closing the assembly, verify 
which LYNXR model is being installed 
by checking the model number printed 
on the PC Boards. (Example: 
SALYNXREN indicates the unit being 
installed is a LYNXR-EN.) 
 
6.  Snap the front assembly to the back 
plate so it is secured by the locking 
tabs. 
1. Slide the control panel onto the 
mounting base locking tabs
 
2.  Bring all wiring through the bottom of 
the mounting base, using one of the 
three wire entry locations, before 
making connections to the control 
panel. 
 
3.  Use tie-wraps to secure the wiring to 
the built-in wire loops as needed. Use 
the two supplied screws to secure the 
control panel to the mounting base. 
 
 