Wiring Connections 
 
Wiring Overview 
 
The following summarizes the connections required. Refer to the Wiring Connections paragraph and the Summary of 
Connections diagram on the inside back cover when making connections. 
  
       
 
 
 
 
 
 
 
 
 
 
 
MXXXX K5108
01009-005-V0
 
 
 
 
 
 
 
 
 
 
 
 
 
Wiring Connections
  
1.  Make Earth Ground Connection
 - 
The designated earth ground terminal (1) must be terminated in a good earth ground 
for the lightning transient protective devices in this product to be effective. The following are examples of good earth 
grounds available at most installations: 
Metal Cold Water Pipe - Secure a non-corrosive metal strap (copper is recommended) to the pipe that is electrically 
connected and secured to which the ground lead. 
AC Power Outlet Ground - Available from 3-prong, 120VAC power outlets only. To test the integrity of the ground 
terminal, use a three-wire circuit tester with neon lamp indicators, such as the UL Listed Ideal Model 61–035, or 
equivalent, available at most electrical supply stores. 
a.  Connect terminal 1 to a good earth ground. 
EARTH GROUND 
See Earth Ground paragraph. 
PHONE LINES
 
Use either the plug-in jacks or 
the screw terminals. 
HARDWIRE ZONE
Supports 1 EOLR supervised zone using either closed 
circuit or open circuit sensors.
 
SOUNDERS
 
The system includes a built-in sounder in the master keypad.  If 
desired, an external bell or piezo sounder can be connected. 
Bell:  Use a 6-14V bell with maximum current drain of 120mA. 
Piezo:  Use a 6-14V piezo sounder with maximum current drain of 
30mA. 
This control complies with NFPA requirements for temporal pulse 
sounding of fire notification appliances.  
Temporal pulse sounding for a fire alarm consists of the following: 
3 pulses – pause – 3 pulses – pause – 3 pulses. . .
 
POWERLINE CARRIER DEVICES 
Supports up to 8 Powerline Carrier 
Devices for turning on/off lights and 
appliances. Requires the use of an 
ADEMCO 1332X10 transformer.
 
AC TRANSFORMER
Use the supplied 
ADEMCO 1332X10 
9VAC, 15VA Plug-in 
Transformer (1332CN in 
Canada).
 
LOCAL SOUNDER DISABLE JUMPER 
Remove the shorting jumper (shunt) to disable local 
sounder, leaving only the external sounder active. 
 
UL NOTE: Do not remove the shorting jumper (the shunt) 
for UL installations. 
LONG RANGE RADIO 
Compatible with the ALARMNET 7845C and 7720 
Devices. 
 
TWO-WAY VOICE 
The LYNXR-EN supports the two-way 
voice feature/Alarm Audio Verification.
The LYNXR and LYNXR24 require the 
installation of the LYNXAVM.
 