Page 1-8
110XiIIIPlus Maintenance Manual
13185L-002 Rev. A 1/24/06
Section 1
System Description
Electrical Requirements
•
Auto-ranging 90–264 VAC; 48–62 Hz
•
5 Amps for entire AC voltage range
•
25 Watts standby power consumption
•
200 Watts maximum power consumption for 110XiIIIPlus-Series
(printing 100% black at 6 ips)
(printing 100% black at 6 ips)
•
Bi-National UL 60950 3rd edition; Certified to CAN/CSA-C22.2 No. 60950-00
Third edition; IEC 950/EN60950:1992 with amendments 1 through 4 (CB
Scheme); EN55022: 1998 Class B; EN55024: 1998; EN61000-3-2, 3 with
amendment A12; Canadian ICES-003, Class B; Argentina 92/98 Phase 3;
Australia AS/NZS 3548; R.O.C. CNS 13438
Third edition; IEC 950/EN60950:1992 with amendments 1 through 4 (CB
Scheme); EN55022: 1998 Class B; EN55024: 1998; EN61000-3-2, 3 with
amendment A12; Canadian ICES-003, Class B; Argentina 92/98 Phase 3;
Australia AS/NZS 3548; R.O.C. CNS 13438
•
CISPR22B-FCC and Canadian DOC class A-Compliant
•
CE-mark compliant
Power Cord Specifications
•
The overall length must be less than 9.8
′ (3.0 m).
•
It must be rated for at least 5 A, 250 V.
•
Refer to
. The chassis ground (earth) must be connected to ensure safety
and reduce electromagnetic interference. The ground connection is handled by the
third wire (earth) in the power cord.
third wire (earth) in the power cord.
•
The AC power plug and IEC 320 connector must bear the certification mark of at
least one of the international safety organizations shown in
least one of the international safety organizations shown in
.
Figure 1-2. AC Power Cord
Figure 1-3. International Safety Organizations Symbols
AC power
plug for
your country
3-conductor
<HAR> cable
IEC 320
connector
Contact
view
Neutral
Live
Earth