Intel DC P3600 SSDPEDME800G410 Benutzerhandbuch

Produktcode
SSDPEDME800G410
Seite von 43
 
 
Intel
®
 Solid-State Drive DC P3600 Series 
 
Product Specification 
October 2014 
32 
 
 
330569-004US 
Appendix A   IDENTIFY Data Structure 
Table 29:  Identify Controller 
Bytes 
F = Fixed 
V = Variable 
X = Both 
Default 
Value 
Interpretation 
Description 
1-0 
F 
8086h 
Contains the company vendor 
identifier that is assigned by the PCI 
SIG 
PCI Vendor ID (VID) 
3-2 
F 
8086h 
Contains the company vendor 
identifier that is assigned by the PCI 
SIG for subsystem 
PCI Subsystem Vendor ID (SSVID) 
23-4 
V 
varies 
Contains the serial number for the 
NVM subsystem 
Serial Number (SN) 
63-24 
V 
varies 
Contains the serial number for the 
NVM subsystem that is assigned by 
the vendor as an ASCII string 
Model Number (MN) 
71-64 
V 
varies 
Contains the currently active firmware 
revision for the NVM subsystem 
Firmware Revision (FR) 
72 
F 
0h 
Recommended Arbitration Burst size 
equals 1 
Recommended Arbitration Burst (RAB) 
75-73 
F 
5CD2E4h 
Contains the Organization Unique 
Identifier (OUI) for the controller vendor 
IEEE OUI Identifier (IEEE) 
76 
X 
0h 
No of multiple PCI Express interfaces 
connected to the host, bit 0 determines 
multiple interface  
Multi-Interface Capabilities (MIC) 
77 
F 
05h 
Supports MDTS of 128K 
Maximum Data Transfer Size (MDTS) 
255:78 
 
 
 
Reserved 
257-256 
F 
07h 
Supports Security Send/Receive, 
Format NVM and Firmware 
Activate/Download 
Optional Admin Command Support (OACS) 
258 
F 
03h 
Supports up to 3 concurrently 
outstanding abort commands 
Abort Command Limit (ACL) 
259 
F 
03h 
Supports up to 3 concurrently 
outstanding asynchronous event 
requests 
Asynchronous Event Request Limit (AERL) 
260 
X 
03h 
Single slot 
Read/write capable 
Firmware Updates (FRMW) 
261 
X 
0h 
SMART/Health Log Support per drive 
not per namespace 
Log Page Attributes (LPA) 
262 
F 
3Fh 
Number of Error Information log 
entries equals 64 
Error Log Page Entries (ELPE) 
263 
F 
0h 
Number of NVM Express* power 
states equal 1 
Number of Power States Support (NPSS) 
264 
F 
0h 
Configuration settings for Admin 
Vendor Specific command handling 
Admin Vendor Specific Command Configuration 
(AVSCC) 
511-265 
 
 
 
Reserved 
512 
F 
66h 
Required and max submission queue 
entry size is 64 Byte 
Submission Queue Entry Size (SQES) 
513 
F 
44h 
Required and max submission queue 
entry size is 16 Byte 
Completion Queue Entry Size (CQES) 
515-514 
 
 
 
Reserved 
519-516 
F 
01h 
Supports single namespace 
Number of Namespaces (NN) 
521-520 
F 
06h 
Supports Dataset Management and 
Write Uncorrectable optional NVMe* 
commands. 
Optional NVMe* Command Support (ONCS)