Intel DC P3600 SSDPEDME800G410 Manuale Utente
Codici prodotto
SSDPEDME800G410
Intel
®
Solid-State Drive DC P3600 Series
Product Specification
October 2014
32
330569-004US
Appendix A IDENTIFY Data Structure
Table 29: Identify Controller
Bytes
F = Fixed
V = Variable
X = Both
Default
Value
Interpretation
Description
1-0
F
8086h
Contains the company vendor
identifier that is assigned by the PCI
SIG
identifier that is assigned by the PCI
SIG
PCI Vendor ID (VID)
3-2
F
8086h
Contains the company vendor
identifier that is assigned by the PCI
SIG for subsystem
identifier that is assigned by the PCI
SIG for subsystem
PCI Subsystem Vendor ID (SSVID)
23-4
V
varies
Contains the serial number for the
NVM subsystem
NVM subsystem
Serial Number (SN)
63-24
V
varies
Contains the serial number for the
NVM subsystem that is assigned by
the vendor as an ASCII string
NVM subsystem that is assigned by
the vendor as an ASCII string
Model Number (MN)
71-64
V
varies
Contains the currently active firmware
revision for the NVM subsystem
revision for the NVM subsystem
Firmware Revision (FR)
72
F
0h
Recommended Arbitration Burst size
equals 1
equals 1
Recommended Arbitration Burst (RAB)
75-73
F
5CD2E4h
Contains the Organization Unique
Identifier (OUI) for the controller vendor
Identifier (OUI) for the controller vendor
IEEE OUI Identifier (IEEE)
76
X
0h
No of multiple PCI Express interfaces
connected to the host, bit 0 determines
multiple interface
connected to the host, bit 0 determines
multiple interface
Multi-Interface Capabilities (MIC)
77
F
05h
Supports MDTS of 128K
Maximum Data Transfer Size (MDTS)
255:78
Reserved
257-256
F
07h
Supports Security Send/Receive,
Format NVM and Firmware
Activate/Download
Format NVM and Firmware
Activate/Download
Optional Admin Command Support (OACS)
258
F
03h
Supports up to 3 concurrently
outstanding abort commands
outstanding abort commands
Abort Command Limit (ACL)
259
F
03h
Supports up to 3 concurrently
outstanding asynchronous event
requests
outstanding asynchronous event
requests
Asynchronous Event Request Limit (AERL)
260
X
03h
Single slot
Read/write capable
Read/write capable
Firmware Updates (FRMW)
261
X
0h
SMART/Health Log Support per drive
not per namespace
not per namespace
Log Page Attributes (LPA)
262
F
3Fh
Number of Error Information log
entries equals 64
entries equals 64
Error Log Page Entries (ELPE)
263
F
0h
Number of NVM Express* power
states equal 1
states equal 1
Number of Power States Support (NPSS)
264
F
0h
Configuration settings for Admin
Vendor Specific command handling
Vendor Specific command handling
Admin Vendor Specific Command Configuration
(AVSCC)
511-265
Reserved
512
F
66h
Required and max submission queue
entry size is 64 Byte
entry size is 64 Byte
Submission Queue Entry Size (SQES)
513
F
44h
Required and max submission queue
entry size is 16 Byte
entry size is 16 Byte
Completion Queue Entry Size (CQES)
515-514
Reserved
519-516
F
01h
Supports single namespace
Number of Namespaces (NN)
521-520
F
06h
Supports Dataset Management and
Write Uncorrectable optional NVMe*
commands.
Write Uncorrectable optional NVMe*
commands.
Optional NVMe* Command Support (ONCS)