Seite von 50
4BJumper Block Settings 
Intel® Compute Module MFS5000SI TPS  
 
 
 
Revision 1.4 
Intel order number: E15154-007 
28 
4.  Move jumper from Default operating position (pins 2-3) to “Enabled” position (pins 1-2) 
5.  Close the compute module 
6.  Reconnect AC power and power up the compute module 
7.  Perform standard BMC firmware update procedure through the Intel® Modular Server Control 
software  
8.  Power down and remove AC power 
9.  Remove compute module from the server system 
10.  Move jumper from “Enabled” position (pins 1-2) to “Disabled” position (pins 2-3) 
11.  Close the server system 
12.  Reinstall the compute module into the modular server chassis 
13.  Reconnect AC power and power up the compute module 
Note:
 Normal BMC functionality (for example, KVM, monitoring, and remote media) is disabled with the 
force BMC update jumper set to the “Enabled” position. The server should never be run with the BMC 
force update jumper set in this position and should only be used when the standard firmware update 
process fails. This jumper should remain in the default – disabled position when the server is running 
normally.  
5.1.3 
System Status LED – BMC Initialization 
When the AC power is first applied to the system and 5V-STBY is present, the Integrated BMC controller 
on the server board requires 15-20 seconds to initialize. During this time, the system status LED blinks, 
alternating between amber and green, and the power button functionality of the control panel is disabled, 
preventing the server from powering up. Once BMC initialization has completed, the status LED stops 
blinking and power button functionality is restored. The power button can then be used to turn on the 
server.