3M Low power connector ATT.CALC.CROSS_SECTION_FLEXIBLE: 0.3-0.56 mm² ATT.CALC.CROSS_SECTION_RIGID: 0.3-0.56 mm² Number of p 37303-2124-000 FL Datenbogen

Produktcode
37303-2124-000 FL
Seite von 8
Product Information
Mini Clamp Wiremount Socket Connector
3M Deutschland GmbH 
Tel.:    02131 / 14 2040
                                      
2 - 8
  
            February 2004
Electronic Solutions 
Fax.:   02131 / 14 2065
Carl-Schurz-Straße 1 
E-Mail:  3minterconnects.de
41453 Neuss
COMPATIBLE OBJECT
1. Compatible connectors
3M Brand : 3710X-XXXX-000 XX :Mini-Clamp wire mount plug connector.
2. Compatible cable
Conductor cross sectional area
AWG20
26
0.14
0.5mm2 
Conductor material
Tin plating annealed copper wire, High strength copper alloy wire,
Copper alloy wire
Conductor structure
Stranded wire, Tin overcoat wire, Solid wire
Conductor construction
AWG20(0.5sq) 
19/0.20
20/0.18
21/0.18
AWG22(0.3sq) 
1/0.643
7/0.254
12/0.18
17/0.16
3/20/0.08
60/0.08
AWG24(0.2sq) 
7/0.20
11/0.16
40/0.08
AWG25(0.18sq) 
7/0.18
36/0.08
37/0.08
7/13/0.05
AWG26(0.14sq) 
7/0.16
30/0.08
7/11/0.05
Isolation material
Heat-resistant vinyl, Half rigid vinyl, Cure PE, ETFE,
Isolation outside diameter
0.8
2.0
  Above adaptation electric wire is an extract from evaluation electric wire and doesnot evaluate all
combinations. Detailed information please ask the sales person incharge.
  This connector recommend electric wire witch is stranded wire of pitch equal to orless than 20
times of conductor outside diameter prescribed with section A4-2-4-3in “Insulated conductors for
power-operated electronic devices” by CSA standardC22.2No.16-1980
There is the thing which even
pitch more than this conforms to.Detailed information please ask the sales person in charge.
  On flat cable, IDC is possible by tearing it up if it is welding cable. In addition, with flat cable of
pushing out molding, IDC is possible by dividing quality ofinsulation with cutters equally. 
Not being
shown electric wire.
  If it is electric wire of seven twisting on AWG 28, it is almost meets. Detailed
information please ask the sales person in charge.
 
Please ask the sales person in charge on junction of shielding wire.
3. Recommendation tool
IDC by pliers
To use base plate (10986, 3771) together in 3M hand press machine (10985, 3640, 3335), and platen
(3442-1A),Can make IDC which height adjusts for 3 with height gauge (3436-1A).
4. An instruction manual
ER-077
Mini-Clamp connector IDC sequence of operation book
5. Caution of operation
Please use it for do not add force to IDC part (don’t pull electric wire).
Demolition at having pulled electric wire changes by thickness of electric wire.
Please install it so that connected load more than 10 N is not added per wire.
Please don’t IDC without jig (for example, dukes / finger).
Note
A breaking strength ability value at having pulled it to the direction that electric wire passed through.
Above numeric value is changed by combination of connector and electric wire. It mentions typical numeric
value example here.
Example 1) At the time of combination with UL1723, AWG22 (1/0.643), finish contour f 1.36, FEP isolation
outer bark electric wire made in Showa Electric Wire & Cable Co.,Ltd. and 37104-2165-000 FL made in 3M
An average of 84.7 N (the fewest 78.5N)