Safety Warnings
1.1
Use for Intended Purpose
• The respective multimeter is a portable device which can be 
held in the hand during the performance of measurements.
• Only those types of measurements described in chapter 5 may 
be performed with the measuring instrument.
• The measuring instrument, including measurement cables and 
plug-on test probes, may only be utilized within the specified 
measuring category (see page 61 and the tablon page 8 
regarding significance).
• Overload limits may not be exceeded. See technical data on 
page 56 for overload values and overload limits.
• Measurements may only be performed under the specified 
ambient conditions. See page 59 regarding operating 
temperature range and relative humidity.
• The measuring instrument may only be used in accordance 
with the specified degree of protection (IP code) (see page 61).
1.2
Meanings of Danger Symbols
Warning concerning a point of danger 
(attention: observe documentation!)
Warning concerning dangerous voltage at the measurement 
input: U > 15 V AC or U > 25 V DC
1.3
Meanings of Acoustic Warning Signals
Voltage warning: > 1000 V (intermittent acoustic signal) 
Current warning: > 11 A (continuous acoustic signal)
!