Transmission Mode  
 
The transmission mode (Sub index 2) for Objects 1800 and 1801 can be configured as described below: 
 
Transfer 
Value 
(Dec) 
Transmission Mode 
Notes 
Cyclic 
Acyclic 
Synchro
nous 
Asynchronous 
RTR 
Only 
 
 
 
Send  PDO  on  first sync 
message  following  an 
event 
1-240 
 
 
 
Send PDO every x sync 
messages 
241-251 
Reserved 
252 
 
 
 
Receive  Sync  and  send 
PDO on remote request 
253 
 
 
 
 
Update  data  and  send 
PDO on remote request 
254 
 
 
 
 
Send PDO on event 
255 
 
 
 
 
Send PDO on Event 
 
Inhibit Time  
 
For  "Transmit  PDOs",  the  "inhibit  time"  for  PDO 
transmissions can be entered in this 16 bit field. If 
data is changed, the PDO  sender checks whether 
an  "inhibit  time"  has  expired  since  the  last 
transmission.  A  new  PDO  transmission  can  only 
take  place  if  the  "inhibit  time"  has  expired.  The 
"inhibit 
time" 
is 
useful 
for 
asynchronous 
transmission (transmission mode 254 and 255), to 
avoid overloads on the CAN bus.  
 
Event Timer  
 
The  "event  timer"  only  works  in  asynchronous 
transmission  mode  (transmission  mode  254  and 
255). If the data changes before the "event timer"  
 
 
expires, a temporary telegram is sent. If a value > 
0 is written in this 16-bit field, the transmit  PDO is 
always  sent  after  the  "event  timer"  expires.  The 
value  is  written  in  sub  index  5  of  a  transmit  PDO. 
The  data transfer also takes place with no change 
to data. The range is between 1-65536 ms. 
 
Cyclic Timer 
 
The  cyclic  timer  is  useful  to  set  the  position 
transmission  to  cyclic  mode.  The  cyclic  timer  can 
be  programmed  from  0ms  to  65536ms.  When 
enabled,  the  ACS  transmits  the  position  value 
contained  in  the  PDO,  at  constant  prescribed 
intervals even if there is no change in the position 
value. Object 2200h is used to set the cyclic timer 
value.