Finder Accessories for series 56: socket series 96 96.02 96.02 Datenbogen

Produktcode
96.02
Seite von 10
3
C:
Option 3, 5, 54
LED (AC)
C:
Option 6, 7, 74
Double LED
(DC non-polarized) 
C:
Option 8, 9, 94
LED + diode (DC, polarity
positive to pin 7) - 
(56.32 only)
Example: 56 series plug-in relay, 2 CO (DPDT), 12 V DC coil, lockable test button and mechanical indicator.
A: 
Contact material
0 = Standard AgNi
2 = AgCdO
4 = AgSnO
2
B: 
Contact circuit
0 = CO (nPDT)
3 = NO (nPST), ≥ 1.5 mm 
contact gap 
Series
Type
3 = Plug-in
4 = PCB
No. of poles
2 = 2 pole, 12 A
4 = 4 pole, 12 A
Coil version
8 = AC (50/60 Hz) 
9 = DC
Coil voltage
See coil specifications
3
2
0
0
9
D: 
Special versions
0
= Standard
1
= Wash tight (RT III) for 56.42 and 
56.44 only
6
= Rear flange mount (4 pole only) 
8
= Rear 35 mm rail mount (4 pole only) 
For other mounting options see page 6
C: 
Options
0
= None
2
= Mechanical indicator 
3* = LED (AC)
4
= Lockable test button+mechanical indicator 
5* = Lockable test button + LED (AC) 
54* = Lockable test button + LED (AC) +
mechanical indicator 
6* = Double LED (DC non-polarized)
7* = Lockable test button + double LED 
(DC non-polarized)
74* = Lockable test button + double LED 
(DC non-polarized) + mechanical indicator
8* = LED + diode (DC, polarity positive 
to pin 7) for 56.32 only 
9* = Lockable test button + LED + diode
(DC, polarity positive to pin 7) for 
56.32 only 
94* = Lockable test button + LED + diode
(DC, polarity positive to pin 7)  +
mechanical indicator for 56.32 only
* Options not available for 220 V DC and
400 V AC versions.
4
0
Ordering information
A
B
C
D
.
.
.
.
0 1 2
5 6
Lockable test button and mechanical flag indicator (0040, 0050, 0054, 0070, 0074, 0090, 0094)
The dual-purpose Finder test button can be used in two ways:
Case 1) The plastic pip (located directly above the test button) remains intact. In this case, when the
test button is pushed, the contacts operate. When the test button is released the contacts return to their
former state.
Case 2) The plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition to
the above function), when the test button is pushed and rotated, the contacts are latched in the 
operating state, and remain so until the test button is rotated back to its former position.
In both cases ensure that the test button actuation is swift and decisive.
Type
Coil version A
B
C
D
56.32 AC
- 2 - 4
0
0 - 2 - 3 - 
- 5
0
AC
0 - 2 - 4
0
54
/
AC
0 - 2 - 4
3
0 - 3 - 5
0
DC
- 2 - 4
0
0 - 2 - 
- 6 - 7 - 8 - 9 0
DC
0 - 2 - 4
0
74 - 94
/
56.34 AC
- 2 - 4
0
- 2 - 3 - - 5
- 6 - 8
AC
0 - 2 - 4
0
54
/
AC
0 - 2 - 4
0 - 3
0 - 3 - 5
0
DC
- 2 - 4
0
- 2 - - 6 - 7
- 6 - 8
DC
0 - 2 - 4
0
74
/
56.42 DC
- 2 - 4
0
0
- 1
AC
0 - 2 - 4
0 - 3
0
0 - 1
56.44 AC-DC
- 2 - 4
0
0
- 1
AC
0 - 2 - 4
0 - 3
0
0 - 1
Selecting features and options: only combinations in the same row are possible.
Preferred selections for best availability are shown in bold.
56 Series - Miniature power relays 12 A
Descriptions: options and special versions
1
2
3
Special versions for Rail Applications on request
E
U
RO
PE
AN
  
 E
U
RO
P E A N
P A
T E
N T
VII-2012, www
.finder
net.com