Finder Accessories for series 56: socket series 96 96.02 96.02 Datenbogen

Produktcode
96.02
Seite von 10
56 Series - Miniature power relays 12 A
5
Nominal
Coil
Operating range
Resistance
Rated coil
voltage
code
consumption
U
N
U
min
*
U
max
R
at U
N
(50Hz)
V
V
V
Ω
mA
6
8.006
4.8
6.6
5.7
300
12
8.012
9.6
13.2
22
150
24
8.024
19.2
26.4
81
90
48
8.048
38.4
52.8
380
37
60
8.060
48
66
600
30
110
8.110
88
121
1,900
16.5
120
8.120
96
132
2,560
13.4
230
8.230
184
253
7,700
9
240
8.240
192
264
10,000
7.5
400
8.400
320
440
26,000
4.9
Nominal
Coil
Operating range
Resistance Rated coil
voltage
code
consumption
U
N
U
min
U
max
R
at U
N
V
V
V
Ω
mA
6
9.006
4.8
6.6
40
150
12
9.012
9.6
13.2
140
86
24
9.024
19.2
26.4
600
40
48
9.048
38.4
52.8
2,400
20
60
9.060
48
66
4,000
15
110
9.110
88
121
12,500
8.8
125
9.125
100
138
17,300
7.2
220
9.220
176
242
54,000
4
Nominal
Coil
Operating range
Resistance Rated coil
voltage
code
consumption
U
N
U
min
*
U
max
R
at U
N
(50Hz)
V
V
V
Ω
mA
6
8.006
4.8
6.6
12
200
12
8.012
9.6
13.2
50
97
24
8.024
19.2
26.4
190
53
48
8.048
38.4
52.8
770
25
60
8.060
48
66
1,200
21
110
8.110
88
121
3,940
12.5
120
8.120
96
132
4,700
12
230
8.230
184
253
17,000
6
240
8.240
192
264
19,100
5.3
AC coil data, 2 pole relay
DC coil data, 2 pole relay
Nominal
Coil
Operating range
Resistance Rated coil
voltage
code
consumption
U
N
U
min
U
max
R
at U
N
V
V
V
Ω
mA
6
9.006
5.1
6.6
32.5
185
12
9.012
10.2
13.2
123
97
24
9.024
20.4
26.4
490
49
48
9.048
40.8
52.8
1,800
27
60
9.060
51
66
3,000
20
110
9.110
93.5
121
10,400
10.5
125
9.125
107
138
14,200
8.8
220
9.220
187
242
44,000
5
AC coil data, 4 pole relay or 4 NO
DC coil data, 4 pole relay
Coil specifications
- Max. permitted coil voltage.
- Min. pick-up voltage with coil at ambient temperature.
R 56 - AC coil operating range v ambient temperature
2 pole relay
R 56 - DC coil operating range v ambient temperature
2 pole relay
R 56 - DC coil operating range v ambient temperature
4 pole relay
R 56 - AC coil operating range v ambient temperature
4 pole relay or 4 NO
- Max. permitted coil voltage.
- Min. pick-up voltage with coil at ambient temperature.
U
min 
= 0.85 U
N
for normally open version.
U
min 
= 0.85 U
N
for normally open version.
normally open version
changeover version
normally open version
changeover version
VII-2012, www
.finder
net.com