CHIPDRIVE CLOUD 4700F 905511 Datenbogen
![CHIPDRIVE](https://files.manualsbrain.com/attachments/451dc40d795cac9edf16be3ec02b8e78c3b9562a/common/fit/150/50/5467c85f6c4d55958e03bfac7016f145b3d6b88e84b0e039a542ce1c15c1/brand_logo.gif)
Produktcode
905511
CLOUD
47
X
0
F
R
EFERENCE
M
ANUAL
80
Output:
For retrieving all settings (0xFE), the output will be:
For retrieving current Power up sequence (0xFF), the output will be:
6.3.5.2. CONTACT_EMV_LOOPBACK
This Escape command lets the host force the firmware to perform an EMV Loop-back
application.
application.
Input:
The input buffer contains the escape code value.
Output
:
Output buffer
NULL
Byte0
Byte 1
Byte2
Value Description
0x00
Starts with Class C voltage.
(1.8V – 3V – 5V order)
(1.8V – 3V – 5V order)
Time delay between
resets in milliseconds
resets in milliseconds
Bit Map of all Voltage
Classes
Classes
[Bit0 – Class A; Bit1 –
Class B; Bit2 – Class C]
Class B; Bit2 – Class C]
0x01
Starts with Class A voltage.
(5V – 3V – 1.8V order)
(5V – 3V – 1.8V order)
Byte0
Value Description
0x00
Starts with Class C voltage. (1.8V – 3V – 5V order)
0x01
Starts with Class A voltage. (5V – 3V – 1.8V order)
Byte0
Escape code(0x05)